Unknown

Dataset Information

0

Metal implants influence CT scan parameters leading to increased local radiation exposure: A proposal for correction techniques.


ABSTRACT: Metal implants not only deteriorate image quality, but also increase radiation exposure. The purpose of this study was to evaluate the effect of metal hip prosthesis on absorbed radiation dose and assess the efficacy of organ dose modulation (ODM) and metal artifact reduction (MAR) protocols on dose reduction. An anthropomorphic phantom was scanned with and without bilateral metal hip prostheses, and surface and deep level radiation doses were measured at the abdomen and pelvis. Finally, the absorbed radiation doses at pelvic and abdominal cavities in the reference, ODM, and two MAR scans (Gemstone spectral imaging, GE) were compared. The Mann Whitney-U test and Kruskal-Wallis test were performed to compare the volume CT dose index (CTDIvol) and mean absorbed radiation doses. Unilateral and bilateral metal hip prostheses increased CTDIVOL by 14.4% and 30.5%, respectively. MAR protocols decreased absorbed radiation doses in the pelvis. MAR showed the most significant dose reduction in the deep pelvic cavity followed by ODM. However, MAR protocols increased absorbed radiation doses in the upper abdomen. ODM significantly reduced absorbed radiation in the pelvis and abdomen. In conclusion, metal hip implants increased radiation doses in abdominopelvic CT scans. MAR and ODM techniques reduced absorbed radiation dose in abdominopelvic CT scans with metal hip prostheses.

SUBMITTER: Song OK 

PROVIDER: S-EPMC6707604 | biostudies-other | 2019

REPOSITORIES: biostudies-other

altmetric image

Publications

Metal implants influence CT scan parameters leading to increased local radiation exposure: A proposal for correction techniques.

Song Ok Kyu OK   Chung Yong Eun YE   Seo Nieun N   Baek Song-Ee SE   Choi Jin-Young JY   Park Mi-Suk MS   Kim Myeong-Jin MJ  

PloS one 20190823 8


Metal implants not only deteriorate image quality, but also increase radiation exposure. The purpose of this study was to evaluate the effect of metal hip prosthesis on absorbed radiation dose and assess the efficacy of organ dose modulation (ODM) and metal artifact reduction (MAR) protocols on dose reduction. An anthropomorphic phantom was scanned with and without bilateral metal hip prostheses, and surface and deep level radiation doses were measured at the abdomen and pelvis. Finally, the abs  ...[more]

Similar Datasets

| S-EPMC7848247 | biostudies-literature
| PRJEB25493 | ENA
| S-EPMC4412154 | biostudies-literature
| S-EPMC6333137 | biostudies-literature
| S-EPMC9291820 | biostudies-literature
| S-EPMC9252998 | biostudies-literature
| S-EPMC6892987 | biostudies-literature
| S-EPMC3215690 | biostudies-other