Proteomics

Dataset Information

0

Anion-Exchange Chromatography of Tryptic and Phosphopeptides: WAX vs. SAX and AEX vs. ERLIC


ABSTRACT: At a pH > 5, phosphopeptides have two negative charges per residue and are well-retained in anion-exchange chromatography. However, the peptides with one or two phosphate groups are not separated from the peptides with multiple Asp or Glu residues, which interfere with the identification of phosphopeptides in tryptic digests. At a pH around 2, phosphate residues have just a single negative charge but Asp and Glu have none. This facilitates the separation of phosphopeptides from unmodified acidic peptides. The singly phosphorylated peptides are retained too weakly under these conditions, due to electrostatic repulsion, unless hydrophilic interaction is superimposed in the ERLIC mode (electrostatic repulsion-hydrophilic interaction chromatography). Weak anion-exchange (WAX) and strong anion-exchange (SAX) columns were compared, both with peptide standards and with a complex tryptic digest. The SAX column exhibited higher capacity at pH 6 than did the WAX column. However, only about 60% as many phosphopeptides were identified at pH 6 than via ERLIC at pH 2. In one run, 12,467 phosphopeptides were identified, including 4233 with more than one phosphate. We conclude that chromatography of phosphopeptides is best performed at low pH in the ERLIC mode. Under those conditions the performances of the SAX and WAX materials were comparable.

INSTRUMENT(S): Q Exactive

ORGANISM(S): Homo Sapiens (ncbitaxon:9606)

SUBMITTER: Andrew Alpert  

PROVIDER: MSV000080774 | MassIVE | Wed Mar 29 12:54:00 BST 2017

SECONDARY ACCESSION(S): PXD001333

REPOSITORIES: MassIVE

Dataset's files

Source:
Action DRS
Other
Items per page:
1 - 1 of 1
altmetric image

Publications

Anion-exchange chromatography of phosphopeptides: weak anion exchange versus strong anion exchange and anion-exchange chromatography versus electrostatic repulsion-hydrophilic interaction chromatography.

Alpert Andrew J AJ   Hudecz Otto O   Mechtler Karl K  

Analytical chemistry 20150417 9


Most phosphoproteomics experiments rely on prefractionation of tryptic digests before online liquid chromatography-mass spectrometry. This study compares the potential and limitations of electrostatic repulsion-hydrophilic interaction chromatography (ERLIC) and anion-exchange chromatography (AEX). At a pH higher than 5, phosphopeptides have two negative charges per residue and are well-retained in AEX. However, peptides with one or two phosphate groups are not separated from peptides with multip  ...[more]