Project description:Background:Alternative splicing and isoform level expression profiling is an emerging field of interest within genomics. Splicing sensitive microarrays, with probes targeted to individual exons or exon-junctions, are becoming increasingly popular as a tool capable of both expression profiling and finer scale isoform detection. Despite their intuitive appeal, relatively little is known about the performance of such tools, particularly in comparison with more traditional 3’ targeted microarrays. Here, we use the well studied Microarray Quality Control (MAQC) dataset to benchmark the Affymetrix Exon Array, and compare it to two other popular platforms: Illumina, and Affymetrix U133. Results:We show that at the gene expression level, the Exon Array performs comparably with the two 3’ targeted platforms. However, the interplatform correlation of the results is slightly lower than between the two 3’ arrays. We show that some of the discrepancies stem from the RNA amplification protocols, e.g. the Exon Array is able to detect expression of non-polyadenylated transcripts. More importantly, we show that many other differences result from the ability of the Exon Array to monitor more detailed isoform-level changes; several examples illustrate that changes detected by the 3’ platforms are actually isoform variations, and that the nature of these variations can be resolved using Exon Array data. Finally, we show how the Exon Array can be used to detect alternative isoform differences, such as alternative splicing, transcript termination, and alternative promoter usage. We discuss the possible pitfalls and false positives resulting from isoform-level analysis. Conclusions:The Exon Array is a valuable tool that can be used to profile gene expression while providing important additional information regarding the types of gene isoforms that are expressed and variable. However, analysis of alternative splicing requires much more hands on effort and visualization of results in order to correctly interpret the data, and generally results in considerably higher false positive rates than expression analysis. One of the main sources of error in the MAQC dataset is variation in amplification efficiency across transcripts, which is not adequately corrected using existing statistical methods. We outline approaches to reduce such errors by filtering out potentially problematic data. This SuperSeries is composed of the SubSeries listed below.
Project description:BACKGROUND: Alternative splicing and isoform level expression profiling is an emerging field of interest within genomics. Splicing sensitive microarrays, with probes targeted to individual exons or exon-junctions, are becoming increasingly popular as a tool capable of both expression profiling and finer scale isoform detection. Despite their intuitive appeal, relatively little is known about the performance of such tools, particularly in comparison with more traditional 3' targeted microarrays. Here, we use the well studied Microarray Quality Control (MAQC) dataset to benchmark the Affymetrix Exon Array, and compare it to two other popular platforms: Illumina, and Affymetrix U133. RESULTS: We show that at the gene expression level, the Exon Array performs comparably with the two 3' targeted platforms. However, the interplatform correlation of the results is slightly lower than between the two 3' arrays. We show that some of the discrepancies stem from the RNA amplification protocols, e.g. the Exon Array is able to detect expression of non-polyadenylated transcripts. More importantly, we show that many other differences result from the ability of the Exon Array to monitor more detailed isoform-level changes; several examples illustrate that changes detected by the 3' platforms are actually isoform variations, and that the nature of these variations can be resolved using Exon Array data. Finally, we show how the Exon Array can be used to detect alternative isoform differences, such as alternative splicing, transcript termination, and alternative promoter usage. We discuss the possible pitfalls and false positives resulting from isoform-level analysis. CONCLUSION: The Exon Array is a valuable tool that can be used to profile gene expression while providing important additional information regarding the types of gene isoforms that are expressed and variable. However, analysis of alternative splicing requires much more hands on effort and visualization of results in order to correctly interpret the data, and generally results in considerably higher false positive rates than expression analysis. One of the main sources of error in the MAQC dataset is variation in amplification efficiency across transcripts, most likely caused by joint effects of elevated GC content in the 5' ends of genes and reduced likelihood of random-primed first strand synthesis in the 3' ends of genes. These effects are currently not adequately corrected using existing statistical methods. We outline approaches to reduce such errors by filtering out potentially problematic data.
Project description:Background:Alternative splicing and isoform level expression profiling is an emerging field of interest within genomics. Splicing sensitive microarrays, with probes targeted to individual exons or exon-junctions, are becoming increasingly popular as a tool capable of both expression profiling and finer scale isoform detection. Despite their intuitive appeal, relatively little is known about the performance of such tools, particularly in comparison with more traditional 3’ targeted microarrays. Here, we use the well studied Microarray Quality Control (MAQC) dataset to benchmark the Affymetrix Exon Array, and compare it to two other popular platforms: Illumina, and Affymetrix U133. Results:We show that at the gene expression level, the Exon Array performs comparably with the two 3’ targeted platforms. However, the interplatform correlation of the results is slightly lower than between the two 3’ arrays. We show that some of the discrepancies stem from the RNA amplification protocols, e.g. the Exon Array is able to detect expression of non-polyadenylated transcripts. More importantly, we show that many other differences result from the ability of the Exon Array to monitor more detailed isoform-level changes; several examples illustrate that changes detected by the 3’ platforms are actually isoform variations, and that the nature of these variations can be resolved using Exon Array data. Finally, we show how the Exon Array can be used to detect alternative isoform differences, such as alternative splicing, transcript termination, and alternative promoter usage. We discuss the possible pitfalls and false positives resulting from isoform-level analysis. Conclusions:The Exon Array is a valuable tool that can be used to profile gene expression while providing important additional information regarding the types of gene isoforms that are expressed and variable. However, analysis of alternative splicing requires much more hands on effort and visualization of results in order to correctly interpret the data, and generally results in considerably higher false positive rates than expression analysis. One of the main sources of error in the MAQC dataset is variation in amplification efficiency across transcripts, which is not adequately corrected using existing statistical methods. We outline approaches to reduce such errors by filtering out potentially problematic data. Keywords: Compare the Affymetrix Exon Array 1.0 ST to Illumina, and Affymetrix U133 platforms
Project description:Investigation of whole genome expression profiles during four time points during the intraerythrocytic lifecycle of the malaria parasite Plasmodium falciparum for transcript isoforms using Exon Arrays. The samples used in this study are further described in Turnbull et. al., Simultaneous Genome-Wide Gene Expression and Transcript Isoform Profiling in the Human Malaria Parasite (in review)
Project description:Investigation of whole genome expression profiles during four time points during the intraerythrocytic lifecycle of the malaria parasite Plasmodium falciparum for transcript isoforms using Exon Arrays. The samples used in this study are further described in Turnbull et. al., Simultaneous Genome-Wide Gene Expression and Transcript Isoform Profiling in the Human Malaria Parasite (in review)
Project description:Background:Alternative splicing and isoform level expression profiling is an emerging field of interest within genomics. Splicing sensitive microarrays, with probes targeted to individual exons or exon-junctions, are becoming increasingly popular as a tool capable of both expression profiling and finer scale isoform detection. Despite their intuitive appeal, relatively little is known about the performance of such tools, particularly in comparison with more traditional 3’ targeted microarrays. Here, we use the well studied Microarray Quality Control (MAQC) dataset to benchmark the Affymetrix Exon Array, and compare it to two other popular platforms: Illumina, and Affymetrix U133. Results:We show that at the gene expression level, the Exon Array performs comparably with the two 3’ targeted platforms. However, the interplatform correlation of the results is slightly lower than between the two 3’ arrays. We show that some of the discrepancies stem from the RNA amplification protocols, e.g. the Exon Array is able to detect expression of non-polyadenylated transcripts. More importantly, we show that many other differences result from the ability of the Exon Array to monitor more detailed isoform-level changes; several examples illustrate that changes detected by the 3’ platforms are actually isoform variations, and that the nature of these variations can be resolved using Exon Array data. Finally, we show how the Exon Array can be used to detect alternative isoform differences, such as alternative splicing, transcript termination, and alternative promoter usage. We discuss the possible pitfalls and false positives resulting from isoform-level analysis. Conclusions:The Exon Array is a valuable tool that can be used to profile gene expression while providing important additional information regarding the types of gene isoforms that are expressed and variable. However, analysis of alternative splicing requires much more hands on effort and visualization of results in order to correctly interpret the data, and generally results in considerably higher false positive rates than expression analysis. One of the main sources of error in the MAQC dataset is variation in amplification efficiency across transcripts, which is not adequately corrected using existing statistical methods. We outline approaches to reduce such errors by filtering out potentially problematic data. Keywords: Compare the Affymetrix Exon Array 1.0 ST to Illumina, and Affymetrix U133 platforms
Project description:BackgroundExon arrays provide a way to measure the expression of different isoforms of genes in an organism. Most of the procedures to deal with these arrays are focused on gene expression or on exon expression. Although the only biological analytes that can be properly assigned a concentration are transcripts, there are very few algorithms that focus on them. The reason is that previously developed summarization methods do not work well if applied to transcripts. In addition, gene structure prediction, i.e., the correspondence between probes and novel isoforms, is a field which is still unexplored.ResultsWe have modified and adapted a previous algorithm to take advantage of the special characteristics of the Affymetrix exon arrays. The structure and concentration of transcripts -some of them possibly unknown- in microarray experiments were predicted using this algorithm. Simulations showed that the suggested modifications improved both specificity (SP) and sensitivity (ST) of the predictions. The algorithm was also applied to different real datasets showing its effectiveness and the concordance with PCR validated results.ConclusionsThe proposed algorithm shows a substantial improvement in the performance over the previous version. This improvement is mainly due to the exploitation of the redundancy of the Affymetrix exon arrays. An R-Package of SPACE with the updated algorithms have been developed and is freely available.