Proteomics

Dataset Information

0

SCX_MS raw files and RP_MS raw files


ABSTRACT: A novel one-dimensional on-line pH gradient-eluted strong cation exchange (SCX)-nano-ESI-MS/MS method was developed for protein identification and tested with mixture of six standard proteins, total lysate of HuH7 and N2a cells, as well as membrane fraction of N2a cells. This method utilized an on-line nano-flow SCX column in a nano-LC system coupled with a nano-electrospray high-resolution mass spectrometer. Protein digests were separated on a nano-flow SCX column with a pH gradient and directly introduced into a mass spectrometer through nano-electrospray ionization. SCXLC-MS/MS showed identification capability for higher proportion of basic peptides compared to RPLC-MS/MS method, especially for histidine-containing peptides. Our SCXLC-MS/MS method is an excellent alternative method to the RPLC-MS/MS method for analysis of standard proteins, total cell and membrane proteomes.

INSTRUMENT(S): Q Exactive

ORGANISM(S): Homo Sapiens (human) Mus Musculus (mouse)

TISSUE(S): Cell Culture

SUBMITTER: mai dier  

LAB HEAD: Hu Zhou

PROVIDER: PXD003438 | Pride | 2016-01-28

REPOSITORIES: Pride

Dataset's files

Source:
Action DRS
20141127_SCX_HuH7_1.raw Raw
20141127_SCX_HuH7_2.raw Raw
20141127_SCX_HuH7_3.raw Raw
20141127_SCX_HuH7_4.raw Raw
20141210_RP_HuH7_1.raw Raw
Items per page:
1 - 5 of 28
altmetric image

Publications

Development of Online pH Gradient-Eluted Strong Cation Exchange Nanoelectrospray-Tandem Mass Spectrometry for Proteomic Analysis Facilitating Basic and Histidine-Containing Peptides Identification.

Xu Jingjing J   Gao Jing J   Yu Chengli C   He Han H   Yang Yiming Y   Figeys Daniel D   Zhou Hu H  

Analytical chemistry 20151214 1


A novel one-dimensional online pH gradient-eluted strong cation exchange-nanoelectrospray ionization-tandem mass spectrometry (SCX-nano-ESI-MS/MS) method was developed for protein identification and tested with a mixture of six standard proteins, total lysate of HuH7 and N2a cells, as well as membrane fraction of N2a cells. This method utilized an online nanoflow SCX column in a nano-LC system coupled with a nanoelectrospray high-resolution mass spectrometer. Protein digests were separated on a  ...[more]

Similar Datasets

2024-05-24 | PXD042789 | Pride
2011-12-22 | E-GEOD-30191 | biostudies-arrayexpress
2011-12-22 | E-GEOD-30190 | biostudies-arrayexpress
2022-03-30 | E-MTAB-11106 | biostudies-arrayexpress
2012-05-30 | E-GEOD-38333 | biostudies-arrayexpress
2016-02-19 | E-GEOD-67828 | biostudies-arrayexpress
2022-05-20 | PXD030567 | Pride
2012-01-24 | E-MTAB-961 | biostudies-arrayexpress
2014-12-03 | E-GEOD-62034 | biostudies-arrayexpress
2014-12-03 | E-GEOD-62032 | biostudies-arrayexpress