TKO6: A Peptide Standard to Assess Interference for Unit-Resolved Isobaric Labeling Platforms


ABSTRACT: Protein abundance profiling using isobaric labeling is a well-established quantitative mass spectrometry technique. However, ratio distortion resulting from co-isolated and co-fragmented ions - commonly referred to as interference - remains a caveat of this technique. Tribrid mass spectrometers, such as the Orbitrap Fusion and the Orbitrap Fusion Lumos with a triple mass analyzer configuration, facilitate methods (namely SPS-MS3) that can help alleviate interference. Yet, few standards are available to measure interference. Here we introduce the TKO6 standard that assesses ion interference and is designed specifically for data acquired at low (unit) mass resolution. We use TKO6 to compare the degree of interference in MS2 versus MS3-based quantitation methods, data acquisition methods of different lengths, and ion trap-based TMT reporter ion analysis (IT-MS3). We show that the TKO6 standard is a valuable tool for assessing data quality and is particularly useful for benchmarking ion trap-based SPS-MS3 analyses.

INSTRUMENT(S): Orbitrap Fusion Lumos

ORGANISM(S): Saccharomyces Cerevisiae (baker's Yeast)

SUBMITTER: Joao Paulo  

LAB HEAD: Joao A. Paulo

PROVIDER: PXD011653 | Pride | 2019-03-07

REPOSITORIES: Pride

Dataset's files

Source:
Action DRS
344638_a09034_TK06m_hrMS2.mzIdentML Mzid
344639_a09049_TK06m_hrMS2.mzIdentML Mzid
344640_a09064_TK06m_hrMS2.mzIdentML Mzid
344686_a09151_TKO6_SPSms3.mzIdentML Mzid
344687_a09152_TKO6_SPSms3.mzIdentML Mzid
Items per page:
1 - 5 of 126
altmetric image

Publications

TKO6: A Peptide Standard To Assess Interference for Unit-Resolved Isobaric Labeling Platforms.

Paulo Joao A JA   Navarrete-Perea Jose J   Guha Thakurta Sanjukta S   Gygi Steven P SP  

Journal of proteome research 20181206 1


Protein abundance profiling using isobaric labeling is a well-established quantitative mass spectrometry technique. However, ratio distortion resulting from coisolated and cofragmented ions, commonly referred to as interference, remains a drawback of this strategy. Tribrid mass spectrometers, such as the Orbitrap Fusion and the Orbitrap Fusion Lumos with a triple mass analyzer configuration, facilitate methods (namely, SPS-MS3) that can help alleviate interference. However, few standards are ava  ...[more]

Similar Datasets

2023-06-02 | PXD020392 | Pride
2018-12-04 | PXD011654 | Pride
2022-03-14 | PXD029320 | Pride
2017-08-07 | MSV000081425 | MassIVE
2017-10-26 | PXD008009 | Pride
2016-05-03 | MSV000079696 | MassIVE
2024-09-25 | PXD041381 | Pride
2020-08-24 | PXD018349 | Pride
2023-05-04 | PXD041002 | Pride
2021-12-30 | PXD022721 | Pride