Proteomics

Dataset Information

0

Refinement of Protein Extraction Protocols for Human Peripheral Nerve Tissue


ABSTRACT: Our aim was to establish an effective method for protein extraction from freshly frozen human peripheral nerves and determine the minimum amount required for consistent protein extraction outcomes. Five extraction methods were compared using 8 M Urea and Ripa buffer, using either the Bullet Blender or Bioruptor. Out of the total 2619 identified proteins, protein extraction using Ripa buffer combined with either Bioruptor or the Bullet Blender resulted in the identification of 1582 (60%) and 1615 (62%) proteins, respectively. In contrast, using 8 M Urea and Bioruptor for protein extraction resulted in 1022 proteins (39%), whereas employing the Bullet Blender yielded 1446 proteins (55%). Sample amount, ranging from 0.6 to 10 mg, were prepared with consistent protein extraction outcome obtained for samples ≥ 1.2 mg. Combining Ripa and 8M Urea with Bullet Blender increased protein identification to 2126 (81%). Proteins were classified by their cell components, molecular functions, and biological processes. Furthermore, a subclassification of proteins involved in the extracellular matrix (ECM) was introduced. We recommend the use of Ripa buffer, in combination with 8 M Urea and Bullet Blender for extracting proteins from fresh-frozen human nerves weighing ≥ 1.2 mg.

INSTRUMENT(S): Orbitrap Eclipse

ORGANISM(S): Homo Sapiens (human)

TISSUE(S): Peripheral Nerve

SUBMITTER: Charlotte Welinder  

LAB HEAD: Drifa Frostadottir

PROVIDER: PXD049366 | Pride | 2025-02-21

REPOSITORIES: pride

Dataset's files

Source:
Action DRS
DF6A_600ug_CW_C2312_081.raw Raw
DF6B_1200ug_CW_C2312_083.raw Raw
DF6C_3400ug_CW_C2312_085.raw Raw
DF6D_2200ug_CW_C2312_087.raw Raw
DF6E_6500ug_CW_C2312_089.raw Raw
Items per page:
1 - 5 of 18
altmetric image

Publications

Refinement of Protein Extraction Protocols for Human Peripheral Nerve Tissue.

Frostadottir Drifa D   Welinder Charlotte C   Perez Raquel R   Dahlin Lars B LB  

ACS omega 20250202 5


Our aim was to establish an effective method for protein extraction from freshly frozen human peripheral nerves, determine the minimum amount required for consistent protein extraction outcomes, and assess which method produced the highest number of protein identities. Five extraction methods were compared using 8 M urea and Ripa buffer using either the Bullet Blender or Bioruptor. Out of the total 2619 identified proteins, protein extraction using the Ripa buffer combined with either Bioruptor  ...[more]