Dual fluorescent hollow silica nanofibers for in situ pH monitoring using an optical fiber.


ABSTRACT: This study reports a sensitive and robust pH sensor based on dual fluorescent doped hollow silica nanofibers (hSNFs) for in situ and real-time pH monitoring. Fluorescein isothiocyanate (FITC) and tris(2,2'-bipyridyl)dichlororuthenium(ii) hexahydrate (Ru(BPY)3) were chosen as a pH sensitive dye and reference dye, respectively. hSNFs were synthesized using a two-step method in a reverse micelle system and were shown to have an average length of 6.20 μm and average diameter of 410 nm. The peak intensity ratio of FITC/Ru(BPY)3 was used to calibrate to solution pH changes. An optical-fiber-based fluorescence detection system was developed that enabled feasible and highly efficient near-field fluorescence detection. The developed system enables fully automated fluorescence detection, where components including the light source, detector, and data acquisition unit are all controlled by a computer. The results show that the developed pH sensor works in a linear range of pH 4.0-9.0 with a fast response time of less than 10 s and minimal sample volume of 50 μL, and can be stored under dark conditions for one month without failure. In addition, the as-prepared hSNF-based pH sensors also have excellent long-term durability. Experimental results from ratiometric sensing confirm the high feasibility, accuracy, stability and simplicity of the dual fluorescent hSNF sensors for the detection of pH in real samples.

SUBMITTER: Zhou J 

PROVIDER: S-EPMC10089112 | biostudies-literature | 2023 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dual fluorescent hollow silica nanofibers for <i>in situ</i> pH monitoring using an optical fiber.

Zhou Junhu J   Ren Yundong Y   Nie Yuan Y   Jin Congran C   Park Jiyoon J   Zhang John X J JXJ  

Nanoscale advances 20230206 8


This study reports a sensitive and robust pH sensor based on dual fluorescent doped hollow silica nanofibers (hSNFs) for <i>in situ</i> and real-time pH monitoring. Fluorescein isothiocyanate (FITC) and tris(2,2'-bipyridyl)dichlororuthenium(ii) hexahydrate (Ru(BPY)<sub>3</sub>) were chosen as a pH sensitive dye and reference dye, respectively. hSNFs were synthesized using a two-step method in a reverse micelle system and were shown to have an average length of 6.20 μm and average diameter of 410  ...[more]

Similar Datasets

| S-EPMC10018648 | biostudies-literature
| S-EPMC10103745 | biostudies-literature
| S-EPMC10246652 | biostudies-literature
| S-EPMC9585438 | biostudies-literature
| S-EPMC9930926 | biostudies-literature
| S-EPMC9682885 | biostudies-literature