Accuracy of tooth-implant impressions: Comparison of five different techniques.


ABSTRACT:

Purpose

To compare the accuracy of five different tooth-implant impression techniques.

Materials and methods

In this in vitro, experimental study, an acrylic model containing one bone-level Straumann dental implant at the site of maxillary first molar and an adjacent second premolar prepared for a porcelain fused to metal restoration was used. Impressions were made from the model using five different one-step tooth-implant impression techniques including scanning with an intraoral scanner, occlusal matrix, wax relief, closed-tray, and open-tray techniques. Each technique was repeated 15 times. The impressions were poured with dental stone, and the obtained casts were scanned by a laboratory scanner. The scan file of each technique was compared with the scan file of the original acrylic model by Geomagic Design X software. Data were analyzed by one-way analysis of variance, and Tamhane's post-hoc test (α = 0.05).

Results

For dental implant, intraoral scanning had the highest accuracy (0.1004 mm2 ) followed by open-tray (0.1914 mm2 ), occlusal matrix (0.2101 mm2 ), closed-tray (0.2422 mm2 ), and wax relief (0.2585 mm2 ) techniques (p < 0.05). For the prepared tooth, wax relief (0.0988 mm2 ) had the highest accuracy followed by occlusal matrix (0.1211 mm2 ), open-tray (0.1663 mm2 ), closed-tray (0.1737 mm2 ), and intraoral scanning (0.4903 mm2 ) technique (p < 0.05). For both dental implant and prepared tooth, occlusal matrix (0.2431 mm2 ) had the highest accuracy followed by open-tray (0.2574 mm2 ), wax relief (0.2693 mm2 ), closed-tray (0.2862 mm2 ), and intraoral scanning (0.3192 mm2 ) technique (p > 0.05).

Conclusion

The compared simultaneous tooth-implant impression techniques had comparable accuracy with no significant difference.

SUBMITTER: Fathi A 

PROVIDER: S-EPMC10280615 | biostudies-literature | 2023 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of tooth-implant impressions: Comparison of five different techniques.

Fathi Amirhossein A   Rismanchian Mansour M   Yazdekhasti Atousa A   Salamati Masih M  

Clinical and experimental dental research 20230412 3


<h4>Purpose</h4>To compare the accuracy of five different tooth-implant impression techniques.<h4>Materials and methods</h4>In this in vitro, experimental study, an acrylic model containing one bone-level Straumann dental implant at the site of maxillary first molar and an adjacent second premolar prepared for a porcelain fused to metal restoration was used. Impressions were made from the model using five different one-step tooth-implant impression techniques including scanning with an intraoral  ...[more]

Similar Datasets

| S-EPMC7071446 | biostudies-literature
| S-EPMC7197148 | biostudies-literature
| S-EPMC5350296 | biostudies-literature
| S-EPMC5455646 | biostudies-other
| S-EPMC5973581 | biostudies-literature
| S-EPMC8197588 | biostudies-literature
| S-EPMC8652366 | biostudies-literature
| S-EPMC5647674 | biostudies-literature
| S-EPMC5063298 | biostudies-literature
| S-EPMC8376669 | biostudies-literature