Unknown

Dataset Information

0

Norwegian Version of the Chelsea Critical Care Physical Assessment Tool (CPAx-NOR): Translation, Face Validity, Cross-Cultural Adaptation and Inter-Rater Reliability.


ABSTRACT:

Background

Assessment of physical and respiratory function in the intensive care unit (ICU) is useful for developing an individualized treatment plan and evaluating patient progress. There is a need for measurement tools that are culturally adapted, reliable and easy to use. The Chelsea Critical Care Physical Assessment Tool (CPAx) is a valid measurement tool with strong psychometric properties for the intensive care population. This study aims to translate, adapt and test face validity and inter-rater reliability of the Norwegian version of CPAx (CPAx-NOR) for use in critically ill adult patients receiving prolonged mechanical ventilation.

Method

CPAx-NOR was forward backward translated, culturally adapted and tested by experts and patients for face validity. Thereafter tested by 10 physiotherapists in five hospitals for inter-rater reliability.

Results

The experts and pilot testers reached consensus on the translation and face validity. Patients were tested at time point A (n = 57) and at time point B (n = 53). The reliability of CPAx-NOR at "A" was 0.990 (0.983-0.994) and at "B" 0.994 (0.990-0.997). Based on A+B combined and adjusted, the ICC was 0.990 (95% CI 0.996-0.998). Standard error of measurement (SEM) was 0.68 and the minimal detectable change (MDC) was 1.89. The Bland-Altman plot showed low bias and no sign of heteroscedasticity. CPAx-NOR changed with a mean score of 14.9, and showed a moderate floor effect at the start of physiotherapy and low ceiling effects at discharge.

Conclusion

CPAx-NOR demonstrated good face validity and excellent inter-rater reliability. It can be used as an assessment tool for physical function in critically ill adults receiving prolonged mechanical ventilation in Norway.

SUBMITTER: Schanke CM 

PROVIDER: S-EPMC10419396 | biostudies-literature | 2023 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Norwegian Version of the Chelsea Critical Care Physical Assessment Tool (CPAx-NOR): Translation, Face Validity, Cross-Cultural Adaptation and Inter-Rater Reliability.

Schanke Charlotte Marie CM   Brekka Anne Kristine AK   Rimehaug Stein Arne SA   Klokkerud Mari M   Andersen Tiina Maarit TM  

Journal of clinical medicine 20230731 15


<h4>Background</h4>Assessment of physical and respiratory function in the intensive care unit (ICU) is useful for developing an individualized treatment plan and evaluating patient progress. There is a need for measurement tools that are culturally adapted, reliable and easy to use. The Chelsea Critical Care Physical Assessment Tool (CPAx) is a valid measurement tool with strong psychometric properties for the intensive care population. This study aims to translate, adapt and test face validity  ...[more]

Similar Datasets

| S-EPMC6340836 | biostudies-other
| S-EPMC10159149 | biostudies-literature
| S-EPMC8996054 | biostudies-literature
| S-EPMC8603523 | biostudies-literature
| S-EPMC7733361 | biostudies-literature
| S-EPMC8649621 | biostudies-literature
| S-EPMC9297551 | biostudies-literature
| S-EPMC10696827 | biostudies-literature
| S-EPMC9408768 | biostudies-literature
| S-EPMC10631317 | biostudies-literature