Colorimetric Paper-Based Analytical Devices (PADs) Backed by Chemometrics for Pd(II) Detection.


ABSTRACT: This paper presents the development of cheap and selective Paper-based Analytical Devices (PADs) for selective Pd(II) determination from very acidic aqueous solutions. The PADs were obtained by impregnating two cm-side squares of filter paper with an azoic ligand, (2-(tetrazolylazo)-1,8 dihydroxy naphthalene-3,6,-disulphonic acid), termed TazoC. The so-obtained orange TazoC-PADs interact quickly with Pd(II) in aqueous solutions by forming a complex purple-blue-colored already at pH lower than 2. The dye complexes no other metal ions at such an acidic media, making TazoC-PADs highly selective to Pd(II) detection. Besides, at higher pH values, other cations, for example, Cu(II) and Ni(II), can interact with TazoC through the formation of stable and pink-magenta-colored complexes; however, it is possible to quantify Pd(II) in the presence of other cations using a multivariate approach. To this end, UV-vis spectra of the TazoC-PADs after equilibration with the metal ions solutions were registered in the 300-800 nm wavelength range. By applying Partial Least Square regression (PLS), the whole UV-vis spectra of the TazoC-PADs were related to the Pd(II) concentrations both when present alone in solution and also in the presence of Cu(II) and Ni(II). Tailored PLS models obtained with matrix-matched standard solutions correctly predicted Pd(II) concentrations in unknown samples and tap water spiked with the metal cation, making the method promising for quick and economical sensing of Pd(II).

SUBMITTER: Alberti G 

PROVIDER: S-EPMC10490827 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Colorimetric Paper-Based Analytical Devices (PADs) Backed by Chemometrics for Pd(II) Detection.

Alberti Giancarla G   Magnaghi Lisa Rita LR   Iurato Marzia M   Zanoni Camilla C   Biesuz Raffaela R  

Sensors (Basel, Switzerland) 20230825 17


This paper presents the development of cheap and selective Paper-based Analytical Devices (PADs) for selective Pd(II) determination from very acidic aqueous solutions. The PADs were obtained by impregnating two cm-side squares of filter paper with an azoic ligand, (2-(tetrazolylazo)-1,8 dihydroxy naphthalene-3,6,-disulphonic acid), termed TazoC. The so-obtained orange TazoC-PADs interact quickly with Pd(II) in aqueous solutions by forming a complex purple-blue-colored already at pH lower than 2.  ...[more]

Similar Datasets

| S-EPMC8675014 | biostudies-literature
| S-EPMC3852662 | biostudies-literature
| S-EPMC8026160 | biostudies-literature
| S-EPMC3979282 | biostudies-literature
| S-EPMC5701284 | biostudies-literature
| S-EPMC5975359 | biostudies-literature
| S-EPMC10649804 | biostudies-literature
| S-EPMC7450514 | biostudies-literature
| S-EPMC6030327 | biostudies-literature
| S-EPMC7071557 | biostudies-literature