Unknown

Dataset Information

0

A click-based electrocorticographic brain-computer interface enables long-term high-performance switch-scan spelling.


ABSTRACT: Background Brain-computer interfaces (BCIs) can restore communication in movement- and/or speech-impaired individuals by enabling neural control of computer typing applications. Single command "click" decoders provide a basic yet highly functional capability. Methods We sought to test the performance and long-term stability of click-decoding using a chronically implanted high density electrocorticographic (ECoG) BCI with coverage of the sensorimotor cortex in a human clinical trial participant (ClinicalTrials.gov, NCT03567213) with amyotrophic lateral sclerosis (ALS). We trained the participant's click decoder using a small amount of training data (< 44 minutes across four days) collected up to 21 days prior to BCI use, and then tested it over a period of 90 days without any retraining or updating. Results Using this click decoder to navigate a switch-scanning spelling interface, the study participant was able to maintain a median spelling rate of 10.2 characters per min. Though a transient reduction in signal power modulation interrupted testing with this fixed model, a new click decoder achieved comparable performance despite being trained with even less data (< 15 min, within one day). Conclusion These results demonstrate that a click decoder can be trained with a small ECoG dataset while retaining robust performance for extended periods, providing functional text-based communication to BCI users.

SUBMITTER: Crone N 

PROVIDER: S-EPMC10571601 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Brain-computer interfaces (BCIs) can restore communication in movement- and/or speech-impaired individuals by enabling neural control of computer typing applications. Single command "click" decoders provide a basic yet highly functional capability.<h4>Methods</h4>We sought to test the performance and long-term stability of click-decoding using a chronically implanted high density electrocorticographic (ECoG) BCI with coverage of the sensorimotor cortex in a human clinical tria  ...[more]

Similar Datasets

| S-EPMC11494178 | biostudies-literature
| S-EPMC4041754 | biostudies-literature
| S-EPMC4711808 | biostudies-literature
| S-EPMC9807599 | biostudies-literature
| S-EPMC3566209 | biostudies-other
| S-EPMC6364987 | biostudies-literature
| S-EPMC5818431 | biostudies-literature
| S-EPMC11611966 | biostudies-literature
| S-EPMC8678598 | biostudies-literature