Unknown

Dataset Information

0

Analysis of false-positive and false-negative results in 99mTc-MIBI SPECT/CT parathyroid imaging.


ABSTRACT:

Background

Exact preoperative localization is desirable to perform minimally invasive parathyroidectomy for hyperparathyroidism (HPT). This study aimed to evaluate the diagnostic values of 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) of parathyroid glands by analyzing the relationship between lesion weight and false-negative (FN) results, as well as to explain the possible reason.

Methods

The data from 314 patients with suspected HPT who underwent 99mTc-MIBI SPECT/CT parathyroid imaging between 2011 and 2022 were retrospectively evaluated. The sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of parathyroid 99mTc-MIBI SPECT/CT were calculated, and the false-positive (FP) and FN findings were analyzed.

Results

Accurate localization by 99mTc-MIBI SPECT/CT was significantly associated with the parathyroid hormone (PTH) level. The 99mTc-MIBI SPECT/CT for diagnosis/lesion location reached a sensitivity of 84.6%/56.8%, a PPV of 97.3%/98.4%, an NPV of only 23.7%/4.18%, and an accuracy of 83.4%/57.1%, respectively. The largest diameter, shortest diameter, and lesion volume were lower in the FN group than in the TP group. A total of 7 FP cases were found, including 2 cases of thyroid nodules, 4 cases of thyroid tissue, and 1 case of hibernoma. A total of 45 FN patients, including 321 FN lesions, were confirmed, of which parathyroid hyperplasia accounted for 97.8%. Lesion weights greater than 20 µg were able to be detected, but lightweight lesions less than 100 mg were the principal source of FN results, accounting for approximately 39.3%. With lesion weights 0-100, 101-300, 301-1,000, and >1,000 mg, the FN rate was 70.8% (126/178), 51.8% (103/199), 34.6% (81/234), and 8.33% (11/132), respectively.

Conclusions

99mTc-MIBI SPECT/CT parathyroid imaging provides good sensitivity and high specificity in HPT location. Correct localization by 99mTc-MIBI SPECT/CT correlates positively with lesion weight and PTH levels. The smaller the lesion, the higher the FN rate in 99mTc-MIBI SPECT/CT parathyroid imaging, and lesions weighing less than 100 mg are the main source of FN results in 99mTc-MIBI SPECT/CT parathyroid imaging.

SUBMITTER: Liu Y 

PROVIDER: S-EPMC10722006 | biostudies-literature | 2023 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Analysis of false-positive and false-negative results in <sup>99m</sup>Tc-MIBI SPECT/CT parathyroid imaging.

Liu Yan Y   Yang Lulu L   Xu Hui H   Yang Yiyuan Y   Liang Yiqian Y   Yang Aimin A   Tang Xiaojiang X   Lei Shengkai S   Christakis Ioannis I   Jitpratoom Pornpeera P   Xue Jianjun J  

Quantitative imaging in medicine and surgery 20231106 12


<h4>Background</h4>Exact preoperative localization is desirable to perform minimally invasive parathyroidectomy for hyperparathyroidism (HPT). This study aimed to evaluate the diagnostic values of <sup>99m</sup>Tc-methoxyisobutylisonitrile (<sup>99m</sup>Tc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) of parathyroid glands by analyzing the relationship between lesion weight and false-negative (FN) results, as well as to explain the possible reason.<h4>Methods</  ...[more]

Similar Datasets

| S-EPMC11897698 | biostudies-literature
| S-EPMC4358706 | biostudies-literature
| S-EPMC7699496 | biostudies-literature
| S-EPMC5829113 | biostudies-literature
| S-EPMC5427779 | biostudies-literature
| S-EPMC3716783 | biostudies-other
| S-EPMC11190825 | biostudies-literature
| S-EPMC3785531 | biostudies-other
| S-EPMC7555464 | biostudies-literature
| S-EPMC4753504 | biostudies-other