Five-year follow-up of a posterior chamber phakic intraocular lens with a central hole for correction of myopia.


ABSTRACT:

Purpose

To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes.

Methods

Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany.

Results

From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean age at surgery of 33 years ± 6 (18-48 years), with a 5 years follow-up. CDVA improved from 0.05logMAR ± 0.15 CDVA preoperatively to  - 0.00 ± 0,07 at 5 years and did not change significantly from 3 to 5 years' time (p = 0.266). The mean spherical equivalent (SE) improved from -10.13D ± 3.39 to  - 0.45D ± 0.69. The change in endothelial cell count showed a mean decrease of 1.9% per year throughout the follow-up. Safety and efficacy index were 1.16 and 0.78, respectively. Cataract formation was seen in 2 of 241 eyes (0.8%), but in none of the 45 eyes that finished the 5-year follow-up.

Conclusions

Our data show a good intermediate and long-term stability, efficiency, and safety of ICL V4c phakic lenses in myopic eyes comparable to other known literature.

SUBMITTER: Lwowski C 

PROVIDER: S-EPMC10724086 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Five-year follow-up of a posterior chamber phakic intraocular lens with a central hole for correction of myopia.

Lwowski Christoph C   Van Keer Karel K   Ruscher Tim T   Van Keer Luisa L   Shajari Mehdi M   Kohnen Thomas T  

International ophthalmology 20231107 12


<h4>Purpose</h4>To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes.<h4>Methods</h4>Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany.<h4>Results</h4>From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean  ...[more]

Similar Datasets

| S-EPMC5511534 | biostudies-other
| S-EPMC7668562 | biostudies-literature
| S-EPMC7171658 | biostudies-literature
| S-EPMC8837325 | biostudies-literature
| S-EPMC9008970 | biostudies-literature
| S-EPMC9115804 | biostudies-literature
| S-EPMC8927518 | biostudies-literature
| S-EPMC10091233 | biostudies-literature
| S-EPMC5757340 | biostudies-literature
| S-EPMC5113895 | biostudies-literature