Project description:BackgroundTo evaluate the interpretation and reporting of antinuclear antibodies (ANA) by indirect immunofluorescence assay (IFA) using HEp-2 substrates based on common practice and guidance by the International Consensus on ANA patterns (ICAP).MethodParticipants included two groups [16 clinical laboratories (CL) and 8 in vitro diagnostic manufacturers (IVD)] recruited via an email sent to the Association of Medical Laboratory Immunologists (AMLI) membership. Twelve (n = 12) pre-qualified specimens were distributed to participants for testing, interpretation and reporting HEp-2 IFA. Results obtained were analyzed for accuracy with the intended and consensus response for three main categorical patterns (nuclear, cytoplasmic and mitotic), common patterns and ICAP report nomenclatures. The distributions of antibody titers of specimens were also compared.ResultsLaboratories differed in the categorical patterns reported; 8 reporting all patterns, 3 reporting only nuclear patterns and 5 reporting nuclear patterns with various combinations of other patterns. For all participants, accuracy with the intended response for the categorical nuclear pattern was excellent at 99% [95% confidence interval (CI): 97-100%] compared to 78% [95% CI 67-88%] for the cytoplasmic, and 93% [95% CI 86%-100%] for mitotic patterns. The accuracy was 13% greater for the common nomenclature [87%, 95% CI 82-90%] compared to the ICAP nomenclature [74%, 95% CI 68-79%] for all participants. Participants reporting all three main categories demonstrated better performances compared to those reporting 2 or less categorical patterns. The average accuracies varied between participant groups, however, with the lowest and most variable performances for cytoplasmic pattern specimens. The reported titers for all specimens varied, with the least variability for nuclear patterns and most titer variability associated with cytoplasmic patterns.ConclusionsOur study demonstrated significant accuracy for all participants in identifying the categorical nuclear staining as well as traditional pattern assignments for nuclear patterns. However, there was less consistency in reporting cytoplasmic and mitotic patterns, with implications for assigning competencies and training for clinical laboratory personnel.
Project description:Anti-melanoma differentiation-associated protein 5 (MDA5) antibody (Ab) positive dermatomyositis (anti-MDA5 DM) is a rare systemic autoimmune disease; further, its prognosis can be rapidly fatal due to pulmonary involvement. The identification and quantification of anti-MDA5 Abs, which serve as a highly specific biomarker of the disease, is a critical step for the establishing of both the diagnosis and monitoring of the disease's activity. The development of a simple, fast, low-cost, and specific detection system of anti-MDA5 Ab is therefore highly desirable for the purposes of routine laboratory diagnosis. Here, we developed a human cell line that stably expresses MDA5 and evaluated its analytical performance in order to detect anti-MDA5 Abs by the utilization of indirect immunofluorescence (IIF). Serum samples from 23 anti-MDA5 DM patients and 22 anti-MDA5 Abs negative myositis readings, which were obtained at time of diagnosis, were analyzed by IIF on MDA5-transfected cells. The results were compared with those obtained with specific semi-quantitative (immunodot) and quantitative (ELISA) assays. A specific cytoplasmic pattern was found solely with the sera of anti-MDA5 DM patients. The sensitivity and specificity of IIF on MDA5-transfected cells were 96% and 100%, respectively, compared with ELISA. The anti-MDA5 Abs titers that were determined by this approach were consistent with the quantitative results obtained by ELISA. Baseline concentrations of anti-MDA5 Abs, either by ELISA or IIF, were not significantly different between surviving and deceased patients; further, they did not differ significantly according to clinical phenotypes. Overall, an IIF cell-based assay constitutes a simple, fast, and low-cost approach to identify and quantify anti-MDA5 Abs; moreover, it is as efficient as ELISA.
Project description:Autoantibodies against soluble liver antigen (SLA) are specific markers for autoimmune hepatitis (AIH) type 1. In contrast to the determination of other AIH-associated autoantibodies by indirect immunofluorescence assay (IFA), detection of anti-SLA relied up to now on ELISA or immunoblot based on bacterially expressed recombinant protein. In order to develop a complementary IFA substrate, SLA isoform 1 was recombinantly produced in the human cell line HEK293 and controlled by a rabbit hyperimmune serum against SLA. The recombinant cells were used in IFA (RC-IFA) to analyze sera from 20 AIH patients with anti-SLA positivity predetermined by ELISA together with 80 controls (20 anti-SLA negative AIH, 15 primary biliary cirrhosis, 15 HCV, and 30 healthy blood donors). Using RC-IFA, anti-SLA was detected in all ELISA positive AIH sera but in none of the controls. Furthermore, a cytosolic fraction of HEK293 containing SLA was able to neutralize the autoantibodies in all positive sera in a dose-dependent manner. HEK293 cells expressing SLA are a valid substrate for the serodiagnosis of AIH relevant autoantibodies by IFA. In concert with cryosections of primate liver, rat kidney, rat liver, rat stomach, and HEp-2 cells, they enable the parallel determination of all autoantibodies associated with autoimmune liver diseases.
Project description:Indirect immunofluorescence based on HEp-2 cell substrate is the most commonly used staining method for antinuclear autoantibodies associated with different types of autoimmune pathologies. The aim of this paper is to design an automatic system to identify the staining patterns based on block segmentation compared to the cell segmentation most used in previous research. Various feature descriptors and classifiers are tested and compared in the classification of the staining pattern of blocks and it is found that the technique of the combination of the local binary pattern and the k-nearest neighbor algorithm achieve the best performance. Relying on the results of block pattern classification, experiments on the whole images show that classifier fusion rules are able to identify the staining patterns of the whole well (specimen image) with a total accuracy of about 94.62%.
Project description:We determined the optimal cutoff titers in admission and convalescent-phase samples for scrub typhus indirect immunofluorescence assay using Bayesian latent class models. Cutoff titers of ≥1:3,200 in an admission sample or of a ≥4-fold rise to ≥1:3,200 in a convalescent-phase sample provided the highest accuracy (sensitivity, 81.6%; specificity, 100%).
Project description:Indirect immunofluorescence assay (IFA) using HEp-2 cells as a substrate is the gold standard for detecting antinuclear antibodies (ANA) in patient serum. However, the ANA IFA has labor-intensive nature of the procedure and lacks adequate standardization. To overcome these drawbacks, the automation has been developed and implemented to the clinical laboratory. The purposes of this study were to evaluate the analytical performance of a fully automated Helios ANA IFA analyzer in a real-life laboratory setting, and to compare the time and the cost of ANA IFA testing before and after adopting the Helios system. A total of 3,276 consecutive serum samples were analyzed for ANA using the Helios system from May to August 2019. The positive/negative results, staining patterns, and endpoint titers were compared between Helios and visual readings. Furthermore, the turnaround time and the number of wells used were compared before and after the introduction of Helios system. Of the 3,276 samples tested, 748 were positive and 2,528 were negative based on visual readings. Using visual reading as the reference standard, the overall relative sensitivity, relative specificity, and concordance of Helios reading were 73.3, 99.4, and 93.4% (κ = 0.80), respectively. For pattern recognition, the overall agreement was 70.1% (298/425) for single patterns, and 72.4% (89/123) for mixed patterns. For titration, there was an agreement of 75.9% (211/278) between automated and classical endpoint titers by regarding within ± one titer difference as acceptable. Helios significantly shortened the median turnaround time from 100.6 to 55.7 h (P < 0.0001). Furthermore, routine use of the system reduced the average number of wells used per test from 4 to 1.5. Helios shows good agreement in distinguishing between positive and negative results. However, it still has limitations in positive/negative discrimination, pattern recognition, and endpoint titer prediction, requiring additional validation of results by human observers. Helios provides significant advantages in routine laboratory ANA IFA work in terms of labor, time, and cost savings. We hope that upgrading and developing softwares with more reliable capabilities will allow automated ANA IFA analyzers to be fully integrated into the routine operations of the clinical laboratory.
Project description:This study investigates the presence of antinuclear antibodies (ANA) in three primary synucleinopathies - Parkinson's disease (PD), multiple system atrophy (MSA), and dementia with Lewy bodies (DLB), compared to healthy controls. Autoinflammatory disorders typically involve the immune system mistakenly attacking the body's own cells and start producing ANA. There is an increasing body of evidence that immune-mediated inflammation is a pathological feature linked to synucleinopathies. To investigate whether this could be autoimmune mediated we analyzed for ANA in the plasma of 25 MSA, 25 PD, and 17 DLB patients, along with 25 healthy controls, using the ANA HEp-2 indirect immunofluorescence antibody assay (ANA HEp-2 IFA). Contrary to initial expectations, results showed ANA HEp-2 positivity in 12% of PD, 8% of MSA patients, 18% of DLB patients, and 17% of healthy controls, indicating no increased prevalence of ANA in synucleinopathies compared to age-matched healthy individuals. Various ANA HEp-2 patterns were identified, but no specific pattern was associated with individual synucleinopathies. We conclude hereby that synucleinopathies are not associated with detectable presence of ANA in plasma.
Project description:BackgroundTORCH including the pathogens of Toxoplasma gondii (TOX), rubella virus (RV), cytomegalovirus (CMV), and herpes simplex virus (HSV) causes intrauterine infections and poses a worldwide threat to women especially in pregnancy. In this study, we described the seasonal difference in TORCH infection and analyzed the anti-TORCH IgM multipositive serum samples by the indirect immunofluorescence assays (IFA).MethodsTo observe the seasonal influence of the anti-TORCH IgG and IgM antibodies, a retrospective study was conducted with 10 669 women (20-40 y old) before pregnancy from August 2016 to July 2017. Totally 199 ELISA anti-TORCH IgM multipositive serum samples were further tested by IFAs for false-positive analysis.ResultsThe prevalence of positive HSV1-IgM, RV-IgM, HSV2-IgM, CMV-IgM, and TOX-IgM in the present population was 6.30%, 2.55%, 1.94%, 1.24%, and 0.67%, respectively. Additionally, the prevalence of positive RV-IgM, CMV-IgM, and HSV1-IgM was statistically different among four seasons, with the highest positive rates of RV-IgM (4.12%) in autumn, CMV-IgM (1.75%) in summer, and HSV1-IgM (7.53%) in winter. The confirmatory IFAs showed that the positive rates of RUV-IgM, CMV-IgM, and HSV2-IgM were significantly different from those in ELISA screening experiments. Interestingly, only 32.7% (65/199) of the TORCH IgM multipositive results were consistent with those by the IFA, indicating that cross-reaction caused false positives were common in ELISA IgM antibody screening.ConclusionThe TORCH infection displayed different prevalence among four seasons in our 12-month retrospective study. The IgM multipositives by ELISA screening may need further confirmation analysis due to its relatively high cross-reaction rate.
Project description:BackgroundThe International Consensus on Antinuclear Antibody (ANA) Patterns (ICAP) has recently proposed nomenclature in order to harmonize ANA indirect immunofluorescence (IIF) pattern reporting. ICAP distinguishes competent-level from expert-level patterns. A survey was organized to evaluate reporting, familiarity, and considered clinical value of ANA IIF patterns.MethodsTwo surveys were distributed by European Autoimmunity Standardization Initiative (EASI) working groups, the International Consensus on ANA Patterns (ICAP) and UK NEQAS to laboratory professionals and clinicians.Results438 laboratory professionals and 248 clinicians from 67 countries responded. Except for dense fine speckled (DFS), the nuclear competent patterns were reported by > 85% of the laboratories. Except for rods and rings, the cytoplasmic competent patterns were reported by > 72% of laboratories. Cytoplasmic IIF staining was considered ANA positive by 55% of clinicians and 62% of laboratory professionals, with geographical and expertise-related differences. Quantification of fluorescence intensity was considered clinically relevant for nuclear patterns, but less so for cytoplasmic and mitotic patterns. Combining IIF with specific extractable nuclear antigens (ENA)/dsDNA antibody testing was considered most informative. Of the nuclear competent patterns, the centromere and homogeneous pattern obtained the highest scores for clinical relevance and the DFS pattern the lowest. Of the cytoplasmic patterns, the reticular/mitochondria-like pattern obtained the highest scores for clinical relevance and the polar/Golgi-like and rods and rings patterns the lowest.ConclusionThis survey confirms that the major nuclear and cytoplasmic ANA IIF patterns are considered clinically important. There is no unanimity on classifying DFS, rods and rings and polar/Golgi-like as a competent pattern and on reporting cytoplasmic patterns as ANA IIF positive.