The effect of real-time EF automatic tool on cardiac ultrasound performance among medical students.


ABSTRACT:

Purpose

Point-of-care ultrasound (POCUS) is a sensitive, safe, and efficient tool used in many clinical settings and is an essential part of medical education in the United States. Numerous studies present improved diagnostic performances and positive clinical outcomes among POCUS users. However, others stress the degree to which the modality is user-dependent, rendering high-quality POCUS training necessary in medical education. In this study, the authors aimed to investigate the potential of an artificial intelligence (AI) based quality indicator tool as a teaching device for cardiac POCUS performance.

Methods

The authors integrated the quality indicator tool into the pre-clinical cardiac ultrasound course for 4th-year medical students and analyzed their performances. The analysis included 60 students who were assigned to one of two groups as follows: the intervention group using the AI-based quality indicator tool and the control group. Quality indicator users utilized the tool during both the course and the final test. At the end of the course, the authors tested the standard echocardiographic views, and an experienced clinician blindly graded the recorded clips. Results were analyzed and compared between the groups.

Results

The results showed an advantage in quality indictor users' median overall scores (P = 0.002) with a relative risk of 2.3 (95% CI: 1.10, 4.93, P = 0.03) for obtaining correct cardiac views. In addition, quality indicator users also had a statistically significant advantage in the overall image quality in various cardiac views.

Conclusions

The AI-based quality indicator improved cardiac ultrasound performances among medical students who were trained with it compared to the control group, even in cardiac views in which the indicator was inactive. Performance scores, as well as image quality, were better in the AI-based group. Such tools can potentially enhance ultrasound training, warranting the expansion of the application to more views and prompting further studies on long-term learning effects.

SUBMITTER: Aronovitz N 

PROVIDER: S-EPMC10977790 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature

altmetric image

Publications

The effect of real-time EF automatic tool on cardiac ultrasound performance among medical students.

Aronovitz Noam N   Hazan Itai I   Jedwab Roni R   Ben Shitrit Itamar I   Quinn Anna A   Wacht Oren O   Fuchs Lior L  

PloS one 20240328 3


<h4>Purpose</h4>Point-of-care ultrasound (POCUS) is a sensitive, safe, and efficient tool used in many clinical settings and is an essential part of medical education in the United States. Numerous studies present improved diagnostic performances and positive clinical outcomes among POCUS users. However, others stress the degree to which the modality is user-dependent, rendering high-quality POCUS training necessary in medical education. In this study, the authors aimed to investigate the potent  ...[more]

Similar Datasets

| S-EPMC6436682 | biostudies-literature
| S-EPMC7077164 | biostudies-literature
| S-EPMC6160010 | biostudies-literature
| S-EPMC5858700 | biostudies-literature
| S-EPMC8608207 | biostudies-literature
| S-EPMC8220763 | biostudies-literature
| S-EPMC3507803 | biostudies-literature
| S-EPMC8199027 | biostudies-literature
| S-EPMC5504851 | biostudies-other
| S-EPMC3727912 | biostudies-literature