Unknown

Dataset Information

0

Evaluation of partial volume correction and analysis of longitudinal [18F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models.


ABSTRACT:

Purpose

We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [18F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM).

Methods

We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden-level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates.

Results

The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability.

Conclusion

The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [18F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test-retest variability.

Clinical trial registration

NCT02640092 and NCT03289143.

SUBMITTER: Sanabria Bohorquez SM 

PROVIDER: S-EPMC11008283 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of partial volume correction and analysis of longitudinal [<sup>18</sup>F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models.

Sanabria Bohórquez Sandra M SM   Baker Suzanne S   Manser Paul T PT   Tonietto Matteo M   Galli Christopher C   Wildsmith Kristin R KR   Zou Yixuan Y   Kerchner Geoffrey A GA   Weimer Robby R   Teng Edmond E  

Frontiers in neuroimaging 20240328


<h4>Purpose</h4>We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [<sup>18</sup>F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM).<h4>Methods</h4>We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods t  ...[more]

Similar Datasets

| S-EPMC6153866 | biostudies-literature
| S-EPMC8454285 | biostudies-literature
| S-EPMC8881582 | biostudies-literature
| S-EPMC5638902 | biostudies-literature
| S-EPMC10213356 | biostudies-literature
| S-EPMC4851886 | biostudies-literature
| S-EPMC5718330 | biostudies-literature
| S-EPMC8638526 | biostudies-literature
| S-EPMC5662681 | biostudies-literature
| S-EPMC7174249 | biostudies-literature