Unknown

Dataset Information

0

Reduction of the pulse duration of the ultrafast laser pulses of the Two-Photon Laser Scanning Microscopy (2PLSM).


ABSTRACT: BACKGROUND: We provide an update of our two-photon laser scanning microscope by compressing or reducing the broadening of the pulse width of ultrafast laser pulses for dispersion precompensation, to enable the pulses to penetrate deeply inside the sample. FINDINGS: The broadening comes as the pulses pass through the optical elements. We enhanced and modified the quality and the sharpness of images by enhancing the resolution using special polarizer namely Glan Laser polarizer GL10. This polarizer consists of two prisms separated by air space. This air separation between the two prisms uses to delay the red wavelength when the light leaves the first prism to the air then to second prism. We note a considerable enhancing with using the GL polarizer, and we can see the details of the leaf structure in early stages when we trying to get focus through z-stacks of images in comparison to exactly the same measurements without using GL polarizer. Hence, with this modification we able to reduce the time of exposure the sample to the laser radiation thereby we will reduce the probability of photobleaching and phototoxicity. When the pulse width reduced, the average power of the laser pulses maintained at a constant level. Significant enhancement is found between the two kinds of images of the Two-Photon Excitation Fluorescence (TPEF). CONCLUSION: In summary reduction the laser pulse width allowed to collect more diffraction orders which will used to form the images. The more diffraction orders the higher resolution images.

SUBMITTER: Reshak AH 

PROVIDER: S-EPMC2519073 | biostudies-literature | 2008

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reduction of the pulse duration of the ultrafast laser pulses of the Two-Photon Laser Scanning Microscopy (2PLSM).

Reshak Ali Hussain AH  

BMC research notes 20080709


<h4>Background</h4>We provide an update of our two-photon laser scanning microscope by compressing or reducing the broadening of the pulse width of ultrafast laser pulses for dispersion precompensation, to enable the pulses to penetrate deeply inside the sample.<h4>Findings</h4>The broadening comes as the pulses pass through the optical elements. We enhanced and modified the quality and the sharpness of images by enhancing the resolution using special polarizer namely Glan Laser polarizer GL10.  ...[more]

Similar Datasets

| S-EPMC4126097 | biostudies-literature
| S-EPMC3739577 | biostudies-literature
| S-EPMC5173245 | biostudies-literature
| S-EPMC4630089 | biostudies-literature
| S-EPMC2756148 | biostudies-other
| S-EPMC8613903 | biostudies-literature
| S-EPMC6959349 | biostudies-literature
| S-EPMC5923200 | biostudies-literature
| S-EPMC3553458 | biostudies-other
| S-EPMC8725169 | biostudies-literature