Unknown

Dataset Information

0

Establishment and validation of a standard protocol for the detection of minimal residual disease in B lineage childhood acute lymphoblastic leukemia by flow cytometry in a multi-center setting.


ABSTRACT: Minimal residual disease detection, used for clinical management of children with acute lymphoblastic leukemia, can be performed by molecular analysis of antigen-receptor gene rearrangements or by flow cytometric analysis of aberrant immunophenotypes. For flow minimal residual disease to be incorporated into larger national and international trials, a quality assured, standardized method is needed which can be performed in a multi-center setting. We report a four color, flow cytometric protocol established and validated by the UK acute lymphoblastic leukemia Flow minimal residual disease group. Quality assurance testing gave high inter-laboratory agreement with no values differing from a median consensus value by more than one point on a logarithmic scale. Prospective screening of B-ALL patients (n=206) showed the method was applicable to 88.3% of patients. The minimal residual disease in bone marrow aspirates was quantified and compared to molecular data. The combined risk category concordance (minimal residual disease levels above or below 0.01%) was 86% (n=134). Thus, this standardized protocol is highly reproducible between laboratories, sensitive, applicable, and shows good concordance with molecular-based analysis.

SUBMITTER: Irving J 

PROVIDER: S-EPMC2688581 | biostudies-literature | 2009 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Establishment and validation of a standard protocol for the detection of minimal residual disease in B lineage childhood acute lymphoblastic leukemia by flow cytometry in a multi-center setting.

Irving Julie J   Jesson Jenny J   Virgo Paul P   Case Marian M   Minto Lynne L   Eyre Lisa L   Noel Nigel N   Johansson Ulrika U   Macey Marion M   Knotts Linda L   Helliwell Margaret M   Davies Paul P   Whitby Liam L   Barnett David D   Hancock Jeremy J   Goulden Nick N   Lawson Sarah S  

Haematologica 20090418 6


Minimal residual disease detection, used for clinical management of children with acute lymphoblastic leukemia, can be performed by molecular analysis of antigen-receptor gene rearrangements or by flow cytometric analysis of aberrant immunophenotypes. For flow minimal residual disease to be incorporated into larger national and international trials, a quality assured, standardized method is needed which can be performed in a multi-center setting. We report a four color, flow cytometric protocol  ...[more]

Similar Datasets

| S-EPMC4486228 | biostudies-literature
| S-EPMC4808717 | biostudies-literature
| S-EPMC4693965 | biostudies-literature
| S-EPMC6854698 | biostudies-literature
| S-EPMC3723913 | biostudies-literature
| S-EPMC5626434 | biostudies-literature
| S-EPMC5352064 | biostudies-literature
| S-EPMC6838385 | biostudies-literature
| S-EPMC2857201 | biostudies-literature
| S-EPMC3290726 | biostudies-literature