Infrared multiphoton dissociation of peptide cations in a dual pressure linear ion trap mass spectrometer.


ABSTRACT: A dual pressure linear ion trap mass spectrometer was modified to permit infrared multiphoton dissociation (IRMPD) in each of the two cells-the first a high pressure cell operated at nominally 5 x 10(-3) Torr and the second a low pressure cell operated at nominally 3 x 10(-4) Torr. When IRMPD was performed in the high pressure cell, most peptide ions did not undergo significant photodissociation; however, in the low pressure cell peptide cations were efficiently dissociated with less than 25 ms of IR irradiation regardless of charge state. IRMPD of peptide cations allowed the detection of low m/z product ions including the y(1) fragments and immonium ions which are not typically observed by ion trap collision induced dissociation (CID). Photodissociation efficiencies of approximately 100% and MS/MS (tandem mass spectrometry) efficiencies of greater than 60% were observed for both multiply and singly protonated peptides. In general, higher sequence coverage of peptides was obtained using IRMPD over CID. Further, greater than 90% of the product ion current in the IRMPD mass spectra of doubly charged peptide ions was composed of singly charged product ions compared to the CID mass spectra in which the abundances of the multiply and singly charged product ions were equally divided. Highly charged primary product ions also underwent efficient photodissociation to yield singly charged secondary product ions, thus simplifying the IRMPD product ion mass spectra.

SUBMITTER: Gardner MW 

PROVIDER: S-EPMC2774747 | biostudies-literature | 2009 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Infrared multiphoton dissociation of peptide cations in a dual pressure linear ion trap mass spectrometer.

Gardner Myles W MW   Smith Suncerae I SI   Ledvina Aaron R AR   Madsen James A JA   Coon Joshua J JJ   Schwartz Jae C JC   Stafford George C GC   Brodbelt Jennifer S JS  

Analytical chemistry 20091001 19


A dual pressure linear ion trap mass spectrometer was modified to permit infrared multiphoton dissociation (IRMPD) in each of the two cells-the first a high pressure cell operated at nominally 5 x 10(-3) Torr and the second a low pressure cell operated at nominally 3 x 10(-4) Torr. When IRMPD was performed in the high pressure cell, most peptide ions did not undergo significant photodissociation; however, in the low pressure cell peptide cations were efficiently dissociated with less than 25 ms  ...[more]

Similar Datasets

| S-EPMC3277647 | biostudies-literature
| S-EPMC5560271 | biostudies-literature
| S-EPMC2847665 | biostudies-literature
| S-EPMC3972134 | biostudies-literature
| S-EPMC2816009 | biostudies-literature
| S-EPMC5690808 | biostudies-literature
| S-EPMC2533114 | biostudies-literature
| S-EPMC3353020 | biostudies-literature
| S-EPMC3254104 | biostudies-literature
| S-EPMC2673988 | biostudies-literature