Unknown

Dataset Information

0

Subnanomolar Detection Limit Application of Ion-Selective Electrodes with Three-Dimensionally Ordered Macroporous (3DOM) Carbon Solid Contacts.


ABSTRACT: Solid-contact ion-selective electrodes (SC-ISEs) can exhibit very low detection limits and, in contrast to conventional ISEs, do not require an optimization of the inner filling solution. This work shows that subnanomolar detection limits can also be achieved with SC-ISEs with three-dimensionally ordered macroporous (3DOM) carbon contacts, which have been shown recently to exhibit excellent long-term stabilities and good resistance to the interferences from oxygen and light. The detection limit of 3DOM carbon-contacted electrodes with plasticized poly(vinyl chloride) as membrane matrix can be improved with a high polymer content of the sensing membrane, a large ratio of ionophore and ionic sites, and conditioning with a low concentration of analyte ions. This permits detection limits as low as 1.6×10(-7) M for K(+) and 4.0×10(-11) M for Ag(+).

SUBMITTER: Lai CZ 

PROVIDER: S-EPMC2795580 | biostudies-literature | 2009 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Subnanomolar Detection Limit Application of Ion-Selective Electrodes with Three-Dimensionally Ordered Macroporous (3DOM) Carbon Solid Contacts.

Lai Chun-Ze CZ   Joyer Marti M MM   Fierke Melissa A MA   Petkovich Nicholas D ND   Stein Andreas A   Bühlmann Philippe P  

Journal of solid state electrochemistry : current research and development in science and technology 20090101 1


Solid-contact ion-selective electrodes (SC-ISEs) can exhibit very low detection limits and, in contrast to conventional ISEs, do not require an optimization of the inner filling solution. This work shows that subnanomolar detection limits can also be achieved with SC-ISEs with three-dimensionally ordered macroporous (3DOM) carbon contacts, which have been shown recently to exhibit excellent long-term stabilities and good resistance to the interferences from oxygen and light. The detection limit  ...[more]

Similar Datasets

| S-EPMC2832318 | biostudies-literature
| S-EPMC4776280 | biostudies-literature
| S-EPMC7697050 | biostudies-literature
| S-EPMC7957766 | biostudies-literature
| S-EPMC9505166 | biostudies-literature
| S-EPMC6766930 | biostudies-literature
| S-EPMC9201804 | biostudies-literature
| S-EPMC8162149 | biostudies-literature
| S-EPMC11007695 | biostudies-literature
| S-EPMC9417045 | biostudies-literature