Lab-on-chip flow injection analysis system without an external pump and valves and integrated with an in line electrochemical detector.


ABSTRACT: Surface energy in small droplets can be used to drive samples through microchannels. When a sample fluid is spontaneously driven through a solution filled microchannel with liquid droplets on its entry (sample) and exit (reservoir) ports, it is termed as a passive pumping device. A passive pump driven microfluidic system integrated with microfabricated planar electrodes or electrode arrays (e.g., interdigitated electrode arrays or microband electrode arrays) can be considered as a manifold for flow injection analysis without an external pump and injector valve. Factors affecting the passive pump driven flow rate in a polydimethylsiloxane (PDMS)-glass hybrid microfluidic system, including the volume, viscosity, and surface tension of the sample solution and the tilt of the microfluidic channel, are analyzed. By placing 2 microL of hexacyanoferrate (II) solutions at the entry port of the device, peak shaped transients were recorded. The peak heights showed linear dependence on the sample concentrations between 3 x 10(-7) and 10(-5) M.

SUBMITTER: Chen IJ 

PROVIDER: S-EPMC2796085 | biostudies-literature | 2009 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Lab-on-chip flow injection analysis system without an external pump and valves and integrated with an in line electrochemical detector.

Chen I-Jane IJ   Lindner Ernö E  

Analytical chemistry 20091201 24


Surface energy in small droplets can be used to drive samples through microchannels. When a sample fluid is spontaneously driven through a solution filled microchannel with liquid droplets on its entry (sample) and exit (reservoir) ports, it is termed as a passive pumping device. A passive pump driven microfluidic system integrated with microfabricated planar electrodes or electrode arrays (e.g., interdigitated electrode arrays or microband electrode arrays) can be considered as a manifold for f  ...[more]

Similar Datasets

| S-EPMC7506898 | biostudies-literature
| S-EPMC2945735 | biostudies-other
| S-EPMC7554035 | biostudies-literature
| S-EPMC8638614 | biostudies-literature
| S-EPMC8892988 | biostudies-literature
| S-EPMC7180603 | biostudies-literature
| S-EPMC4004189 | biostudies-other
| S-EPMC6240576 | biostudies-literature
| S-EPMC7408601 | biostudies-literature
| S-EPMC5384074 | biostudies-literature