Unknown

Dataset Information

0

High-precision recording of the action potential in isolated cardiomyocytes using the near-infrared fluorescent dye di-4-ANBDQBS.


ABSTRACT: The use of voltage-sensitive fluorescent dyes (VSD) for noninvasive measurement of the action potential (AP) in isolated cells has been hindered by low-photon yield of the preparation, dye toxicity, and photodynamic damage. Here we used a new red-shifted VSD, di-4-ANBDQBS, and a fast electron-multiplied charge-coupled device camera for optical AP (OAP) recording in guinea pig cardiac myocytes. Loading di-4-ANBDQBS did not alter APs recorded with micropipette. With short laser exposures (just enough to record one OAP every 1-5 min), di-4-ANBDQBS yielded fluorescent signals with very high signal-to-background ratios (change in fluorescence on depolarization/fluorescence at resting potential: 19.2 ± 4.1%) and signal-to-noise ratios (40 ± 13.2). Quantum chemical calculations comparing the ANBDQ chromophore to the conventional ANEP chromophore showed that the higher wavelength and the greater voltage sensitivity of the former have the same electro-optical origin: a longer path for electron redistribution in the excited state. OAP closely tracked simultaneously recorded electrical APs, permitting measurement of AP duration within 1% error. Prolonged laser exposure caused progressive AP duration prolongation and instability. However, these effects were alleviated or abolished by reducing the dye concentration and by perfusion with antioxidants. Thus the presented technique provides a unique opportunity for noninvasive AP recording in single cardiomyocytes.

SUBMITTER: Warren M 

PROVIDER: S-EPMC2957348 | biostudies-literature | 2010 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

High-precision recording of the action potential in isolated cardiomyocytes using the near-infrared fluorescent dye di-4-ANBDQBS.

Warren Mark M   Spitzer Kenneth W KW   Steadman Bruce W BW   Rees Tyler D TD   Venable Paul P   Taylor Tyson T   Shibayama Junko J   Yan Ping P   Wuskell Joseph P JP   Loew Leslie M LM   Zaitsev Alexey V AV  

American journal of physiology. Heart and circulatory physiology 20100702 4


The use of voltage-sensitive fluorescent dyes (VSD) for noninvasive measurement of the action potential (AP) in isolated cells has been hindered by low-photon yield of the preparation, dye toxicity, and photodynamic damage. Here we used a new red-shifted VSD, di-4-ANBDQBS, and a fast electron-multiplied charge-coupled device camera for optical AP (OAP) recording in guinea pig cardiac myocytes. Loading di-4-ANBDQBS did not alter APs recorded with micropipette. With short laser exposures (just eno  ...[more]

Similar Datasets

| S-EPMC3043135 | biostudies-literature
| S-EPMC6516061 | biostudies-literature
| PRJEB51223 | ENA
| S-EPMC8274942 | biostudies-literature
| S-EPMC4425247 | biostudies-literature
| S-EPMC6239192 | biostudies-literature
| S-EPMC2646119 | biostudies-literature
| S-EPMC7558102 | biostudies-literature
| S-EPMC7855747 | biostudies-literature
| S-EPMC9919055 | biostudies-literature