Unknown

Dataset Information

0

Nucleotide and nucleotide sugar analysis by liquid chromatography-electrospray ionization-mass spectrometry on surface-conditioned porous graphitic carbon.


ABSTRACT: We examined the analysis of nucleotides and nucleotide sugars by chromatography on porous graphitic carbon with mass spectrometric detection, a method that evades contamination of the MS instrument with ion pairing reagent. At first, adenosine triphosphate (ATP) and other triphosphate nucleotides exhibited very poor chromatographic behavior on new columns and could hardly be eluted from columns previously cleaned with trifluoroacetic acid. Satisfactory performance of both new and older columns could, however, be achieved by treatment with reducing agent and, unexpectedly, hydrochloric acid. Over 40 nucleotides could be detected in cell extracts including many isobaric compounds such as ATP, deoxyguanosine diphosphate (dGTP), and phospho-adenosine-5'-phosphosulfate or 3',5'-cyclic adenosine 5'-monophosphate (AMP) and its much more abundant isomer 2',3'-cyclic AMP. A fast sample preparation procedure based on solid-phase extraction on carbon allowed detection of very short-lived analytes such as cytidine 5'-monophosphate (CMP)-2-keto-deoxy-octulosonic acid. In animal cells and plant tissues, about 35 nucleotide sugars were detected, among them rarely considered metabolites such as uridine 5'-diphosphate (UDP)-l-arabinopyranose, UDP-L-arabinofuranose, guanosine 5'-diphosphate (GDP)-L-galactofuranose, UDP-L-rhamnose, and adenosine diphosphate (ADP)-sugars. Surprisingly, UDP-arabinopyranose was also found in Chinese hamster ovary (CHO) cells. Due to the unique structural selectivity of graphitic carbon, the method described herein distinguishes more nucleotides and nucleotide sugars than previously reported approaches.

SUBMITTER: Pabst M 

PROVIDER: S-EPMC2995335 | biostudies-literature | 2010 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Nucleotide and nucleotide sugar analysis by liquid chromatography-electrospray ionization-mass spectrometry on surface-conditioned porous graphitic carbon.

Pabst Martin M   Grass Josephine J   Fischl Richard R   Léonard Renaud R   Jin Chunsheng C   Hinterkörner Georg G   Borth Nicole N   Altmann Friedrich F  

Analytical chemistry 20101102 23


We examined the analysis of nucleotides and nucleotide sugars by chromatography on porous graphitic carbon with mass spectrometric detection, a method that evades contamination of the MS instrument with ion pairing reagent. At first, adenosine triphosphate (ATP) and other triphosphate nucleotides exhibited very poor chromatographic behavior on new columns and could hardly be eluted from columns previously cleaned with trifluoroacetic acid. Satisfactory performance of both new and older columns c  ...[more]

Similar Datasets

| S-EPMC3290520 | biostudies-literature
| S-EPMC4551553 | biostudies-literature
| S-EPMC3769336 | biostudies-literature
| S-EPMC3673025 | biostudies-literature
| S-EPMC3277681 | biostudies-literature
| S-EPMC4394628 | biostudies-literature
| S-EPMC2876209 | biostudies-literature
| S-EPMC7996953 | biostudies-literature
| S-EPMC3880628 | biostudies-literature
| S-EPMC8226321 | biostudies-literature