The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis.


ABSTRACT:

Objective

To meta-analyse the diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis.

Methods

From a comprehensive literature search in MEDLINE, EMBASE, CINAHL and Cochrane (up to November 2009), articles were selected that investigated the diagnostic performance imaging techniques for evaluating hepatic steatosis with histopathology as the reference standard. Cut-off values for the presence of steatosis on liver biopsy were subdivided into four groups: (1) >0, >2 and >5% steatosis; (2) >10, >15 and >20%; (3) >25, >30 and >33%; (4) >50, >60 and >66%. Per group, summary estimates for sensitivity and specificity were calculated. The natural-logarithm of the diagnostic odds ratio (lnDOR) was used as a single indicator of test performance.

Results

46 articles were included. Mean sensitivity estimates for subgroups were 73.3-90.5% (US), 46.1-72.0% (CT), 82.0-97.4% (MRI) and 72.7-88.5% (1H-MRS). Mean specificity ranges were 69.6-85.2% (US), 88.1-94.6% (CT), 76.1-95.3% (MRI) and 92.0-95.7% (1H-MRS). Overall performance (lnDOR) of MRI and 1H-MRS was better than that for US and CT for all subgroups, with significant differences in groups 1 and 2.

Conclusion

MRI and 1H-MRS can be considered techniques of choice for accurate evaluation of hepatic steatosis.

SUBMITTER: Bohte AE 

PROVIDER: S-EPMC2995875 | biostudies-literature | 2011 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis.

Bohte Anneloes E AE   van Werven Jochem R JR   Bipat Shandra S   Stoker Jaap J  

European radiology 20100731 1


<h4>Objective</h4>To meta-analyse the diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis.<h4>Methods</h4>From a comprehensive literature search in MEDLINE, EMBASE, CINAHL and Cochrane (up to November 2009), articles were selected that investigated the diagnostic performance imaging techniques for evaluating hepatic steatosis with histopathology as the reference standard. Cut-off values for the presence of steatosis on liver biopsy were subdivided into four grou  ...[more]

Similar Datasets

| S-EPMC5558105 | biostudies-other
2021-12-01 | GSE184904 | GEO
| S-EPMC4482532 | biostudies-literature
| S-EPMC5814003 | biostudies-literature
| PRJNA767010 | ENA
| S-EPMC8616122 | biostudies-literature
| S-EPMC8511036 | biostudies-literature
| S-EPMC8038574 | biostudies-literature
| S-EPMC9168736 | biostudies-literature
| S-EPMC6283324 | biostudies-literature