Characterization of the evanescent field profile and bound mass sensitivity of a label-free silicon photonic microring resonator biosensing platform.


ABSTRACT: Silicon photonic microring resonators have emerged as a sensitive and highly multiplexed platform for real-time biomolecule detection. Herein, we profile the evanescent decay of device sensitivity towards molecular binding as a function of distance from the microring surface. By growing multilayers of electrostatically bound polymers extending from the sensor surface, we are able to empirically determine that the evanescent field intensity is characterized by a 1/e response decay distance of 63 nm. We then applied this knowledge to study the growth of biomolecular assemblies consisting of alternating layers of biotinylated antibody and streptavidin, which follow a more complex growth pattern. Additionally, by monitoring the shift in microring resonance wavelength upon the deposition of a radioactively labeled protein, the mass sensitivity of the ring resonator platform was determined to be 14.7±6.7 [pg/mm(2)]/?pm. By extrapolating to the instrument noise baseline, the mass/area limit of detection is found to be 1.5±0.7 pg/mm(2). Taking the small surface area of the microring sensor into consideration, this value corresponds to an absolute mass detection limit of 125 ag (i.e. 0.8 zmol of IgG), demonstrating the remarkable sensitivity of this promising label-free biomolecular sensing platform.

SUBMITTER: Luchansky MS 

PROVIDER: S-EPMC2997171 | biostudies-literature | 2010 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Characterization of the evanescent field profile and bound mass sensitivity of a label-free silicon photonic microring resonator biosensing platform.

Luchansky Matthew S MS   Washburn Adam L AL   Martin Teresa A TA   Iqbal Muzammil M   Gunn L Cary LC   Bailey Ryan C RC  

Biosensors & bioelectronics 20100712 4


Silicon photonic microring resonators have emerged as a sensitive and highly multiplexed platform for real-time biomolecule detection. Herein, we profile the evanescent decay of device sensitivity towards molecular binding as a function of distance from the microring surface. By growing multilayers of electrostatically bound polymers extending from the sensor surface, we are able to empirically determine that the evanescent field intensity is characterized by a 1/e response decay distance of 63  ...[more]

Similar Datasets

| S-EPMC10461202 | biostudies-literature
| S-EPMC3241882 | biostudies-literature
| S-EPMC3729447 | biostudies-literature
| S-EPMC3546499 | biostudies-literature
| S-EPMC3367093 | biostudies-literature
| S-EPMC3165060 | biostudies-literature
| S-EPMC3832353 | biostudies-literature
| S-EPMC9599562 | biostudies-literature
| S-EPMC2783283 | biostudies-literature
| S-EPMC2800857 | biostudies-literature