Unknown

Dataset Information

0

Semi-automated non-target processing in GC × GC-MS metabolomics analysis: applicability for biomedical studies.


ABSTRACT: Due to the complexity of typical metabolomics samples and the many steps required to obtain quantitative data in GC × GC-MS consisting of deconvolution, peak picking, peak merging, and integration, the unbiased non-target quantification of GC × GC-MS data still poses a major challenge in metabolomics analysis. The feasibility of using commercially available software for non-target processing of GC × GC-MS data was assessed. For this purpose a set of mouse liver samples (24 study samples and five quality control (QC) samples prepared from the study samples) were measured with GC × GC-MS and GC-MS to study the development and progression of insulin resistance, a primary characteristic of diabetes type 2. A total of 170 and 691 peaks were quantified in, respectively, the GC-MS and GC × GC-MS data for all study and QC samples. The quantitative results for the QC samples were compared to assess the quality of semi-automated GC × GC-MS processing compared to targeted GC-MS processing which involved time-consuming manual correction of all wrongly integrated metabolites and was considered as golden standard. The relative standard deviations (RSDs) obtained with GC × GC-MS were somewhat higher than with GC-MS, due to less accurate processing. Still, the biological information in the study samples was preserved and the added value of GC × GC-MS was demonstrated; many additional candidate biomarkers were found with GC × GC-MS compared to GC-MS. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11306-010-0219-6) contains supplementary material, which is available to authorized users.

SUBMITTER: Koek MM 

PROVIDER: S-EPMC3040320 | biostudies-literature | 2011 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Semi-automated non-target processing in GC × GC-MS metabolomics analysis: applicability for biomedical studies.

Koek Maud M MM   van der Kloet Frans M FM   Kleemann Robert R   Kooistra Teake T   Verheij Elwin R ER   Hankemeier Thomas T  

Metabolomics : Official journal of the Metabolomic Society 20100715 1


Due to the complexity of typical metabolomics samples and the many steps required to obtain quantitative data in GC × GC-MS consisting of deconvolution, peak picking, peak merging, and integration, the unbiased non-target quantification of GC × GC-MS data still poses a major challenge in metabolomics analysis. The feasibility of using commercially available software for non-target processing of GC × GC-MS data was assessed. For this purpose a set of mouse liver samples (24 study samples and five  ...[more]

Similar Datasets

| S-EPMC5084691 | biostudies-literature
| S-EPMC7254393 | biostudies-literature
| S-EPMC2912306 | biostudies-literature
| S-EPMC5544921 | biostudies-literature
| S-EPMC2824679 | biostudies-literature
| S-EPMC6334306 | biostudies-literature
| S-EPMC6523563 | biostudies-literature
| S-BSST1138 | biostudies-other
| S-EPMC5553085 | biostudies-literature
| S-EPMC10458701 | biostudies-literature