Electroosmotic pump performance is affected by concentration polarizations of both electrodes and pump.


ABSTRACT: Current methods of optimizing electroosmotic (EO) pump performance include reducing pore diameter and reducing ionic strength of the pumped electrolyte. However, these approaches each increase the fraction of total ionic current carried by diffuse electric double layer (EDL) counterions. When this fraction becomes significant, concentration polarization (CP) effects become important, and traditional EO pump models are no longer valid. We here report on the first simultaneous concentration field measurements, pH visualizations, flow rate, and voltage measurements on such systems. Together, these measurements elucidate key parameters affecting EO pump performance in the CP dominated regime. Concentration field visualizations show propagating CP enrichment and depletion fronts sourced by our pump substrate and traveling at order mm/min velocities through millimeter-scale channels connected serially to our pump. The observed propagation in millimeter-scale channels is not explained by current propagating CP models. Additionally, visualizations show that CP fronts are sourced by and propagate from the electrodes of our system, and then interact with the EO pump-generated CP zones. With pH visualizations, we directly detect that electrolyte properties vary sharply across the anode enrichment front interface. Our observations lead us to hypothesize possible mechanisms for the propagation of both pump- and electrode-sourced CP zones. Lastly, our experiments show the dynamics associated with the interaction of electrode and membrane CP fronts, and we describe the effect of these phenomena on EO pump flow rates and applied voltages under galvanostatic conditions.

SUBMITTER: Suss ME 

PROVIDER: S-EPMC3079224 | biostudies-literature | 2011 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electroosmotic pump performance is affected by concentration polarizations of both electrodes and pump.

Suss Matthew E ME   Mani Ali A   Zangle Thomas A TA   Santiago Juan G JG  

Sensors and actuators. A, Physical 20110201 2


Current methods of optimizing electroosmotic (EO) pump performance include reducing pore diameter and reducing ionic strength of the pumped electrolyte. However, these approaches each increase the fraction of total ionic current carried by diffuse electric double layer (EDL) counterions. When this fraction becomes significant, concentration polarization (CP) effects become important, and traditional EO pump models are no longer valid. We here report on the first simultaneous concentration field  ...[more]

Similar Datasets

| S-EPMC6190331 | biostudies-literature
| S-EPMC3982979 | biostudies-literature
| S-EPMC3070358 | biostudies-literature
| S-EPMC8293738 | biostudies-literature
| S-EPMC5506946 | biostudies-other
| S-EPMC3831982 | biostudies-literature
| S-EPMC6712053 | biostudies-literature
| S-EPMC4800498 | biostudies-other
| S-EPMC5978176 | biostudies-literature
| S-EPMC6911310 | biostudies-literature