Influence of CT reconstruction settings on extremely low attenuation values for specific gas volume calculation in severe emphysema.


ABSTRACT:

Rationale and objectives

Emphysema is characterized by lung tissue destruction and trapped gas. On computed tomographic (CT) images, this may be expressed by widespread areas with high specific gas volume (SV(g)). SV(g) is highly sensitive to very low attenuation values, which frequently occur in the CT images of patients with severe emphysema. The purpose of the present work was to study if and how different reconstruction settings and different scanners significantly influence SV(g) distribution, particularly in the very low attenuation range.

Materials and methods

Two sets of CT images taken from two different CT scanners at two different lung volumes in 10 healthy volunteers and 18 subjects with severe emphysema were analyzed. Images were reconstructed using two different settings of reconstruction parameters: (1) thin slice thickness and sharp filter and (2) thick slice thickness and smooth filter. For each set of images, average values of SV(g) and their variation (?SV(g)) from total lung capacity to residual volume were calculated in the whole lung.

Results

Very low attenuation values are always present in CT images when reconstructed with thin slice thickness and a sharp filter and in very large numbers in patients with severe emphysema. SV(g) values were in general significantly higher in patients with emphysema than in healthy subjects, at both total lung capacity and residual volume (P < .001), and were significantly influenced by the reconstruction filter (P < .001) and CT scanner (P < .001). ?SV(g) was lower in patients with emphysema than in healthy subjects (P < .001) and was significantly affected by the reconstruction setting but not by the CT scanner.

Conclusions

The disproportionate effect of low-attenuation pixels on SV(g) likely causes overestimation of the severity of emphysema and trapped gas. This can be significantly reduced, however, by using thick slices and a smooth filter for image reconstruction. ?SV(g) is generally robust for quantifying the functional impairment of the lung in severe emphysema.

SUBMITTER: Salito C 

PROVIDER: S-EPMC3167941 | biostudies-literature | 2011 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Influence of CT reconstruction settings on extremely low attenuation values for specific gas volume calculation in severe emphysema.

Salito Caterina C   Woods Jason C JC   Aliverti Andrea A  

Academic radiology 20110712 10


<h4>Rationale and objectives</h4>Emphysema is characterized by lung tissue destruction and trapped gas. On computed tomographic (CT) images, this may be expressed by widespread areas with high specific gas volume (SV(g)). SV(g) is highly sensitive to very low attenuation values, which frequently occur in the CT images of patients with severe emphysema. The purpose of the present work was to study if and how different reconstruction settings and different scanners significantly influence SV(g) di  ...[more]

Similar Datasets

| S-EPMC5812649 | biostudies-literature
| S-EPMC6344385 | biostudies-literature
| S-EPMC6220000 | biostudies-literature
| S-EPMC5407811 | biostudies-literature
| S-EPMC4397043 | biostudies-literature
| S-EPMC4677600 | biostudies-literature
| S-EPMC9317892 | biostudies-literature
| S-EPMC10860741 | biostudies-literature
| S-EPMC9264089 | biostudies-literature
| S-EPMC6916112 | biostudies-literature