Unknown

Dataset Information

0

Loop-mediated isothermal amplification assay for detection of Haemophilus influenzae type b in cerebrospinal fluid.


ABSTRACT: Haemophilus influenzae type b (Hib) is one of the leading causes of meningitis in developing countries. To establish and evaluate a novel loop-mediated isothermal amplification (LAMP) assay for Hib, we designed a LAMP primer set targeting the Hib-specific capsulation locus. LAMP detected 10 copies of purified DNA in a 60-min reaction. This indicated that the detection limit of LAMP was >100-fold lower than the detection limits of both a PCR for the detection of bexA and a nested PCR for Hib (Hib PCR). No H. influenzae, other than Hib or control bacteria, was detected. Linear determination ranged from 10 to 1,000,000 microorganisms per reaction mixture using real-time turbidimetry. We evaluated the Hib LAMP assay using a set of 52 randomly selected cerebrospinal fluid (CSF) specimens obtained from children with suspected meningitis. For comparison, the CSF specimens were tested using a conventional Hib PCR assay. Hib was detected in 30 samples using LAMP and in 22 samples using the Hib PCR assay. The Hib PCR showed a clinical sensitivity of 73.3% and a clinical specificity of 100% relative to the Hib LAMP assay. These results suggest that further development and evaluation of the Hib LAMP will enhance the global diagnostic capability for Hib detection.

SUBMITTER: Kim DW 

PROVIDER: S-EPMC3187296 | biostudies-literature | 2011 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Loop-mediated isothermal amplification assay for detection of Haemophilus influenzae type b in cerebrospinal fluid.

Kim Dong Wook DW   Kilgore Paul Evan PE   Kim Eun Jin EJ   Kim Soon Ae SA   Anh Dang Duc DD   Seki Mitsuko M  

Journal of clinical microbiology 20110810 10


Haemophilus influenzae type b (Hib) is one of the leading causes of meningitis in developing countries. To establish and evaluate a novel loop-mediated isothermal amplification (LAMP) assay for Hib, we designed a LAMP primer set targeting the Hib-specific capsulation locus. LAMP detected 10 copies of purified DNA in a 60-min reaction. This indicated that the detection limit of LAMP was >100-fold lower than the detection limits of both a PCR for the detection of bexA and a nested PCR for Hib (Hib  ...[more]

Similar Datasets

| S-EPMC9069426 | biostudies-literature
| S-EPMC4390149 | biostudies-literature
| S-EPMC4470582 | biostudies-other
| S-EPMC4709847 | biostudies-literature
| S-EPMC5632651 | biostudies-literature
| S-EPMC6023700 | biostudies-literature
| S-EPMC3649941 | biostudies-literature
| S-EPMC2691116 | biostudies-literature
| S-EPMC3550813 | biostudies-literature
| S-EPMC6986840 | biostudies-literature