Unknown

Dataset Information

0

Is high resolution melting analysis (HRMA) accurate for detection of human disease-associated mutations? A meta analysis.


ABSTRACT:

Background

High Resolution Melting Analysis (HRMA) is becoming the preferred method for mutation detection. However, its accuracy in the individual clinical diagnostic setting is variable. To assess the diagnostic accuracy of HRMA for human mutations in comparison to DNA sequencing in different routine clinical settings, we have conducted a meta-analysis of published reports.

Methodology/principal findings

Out of 195 publications obtained from the initial search criteria, thirty-four studies assessing the accuracy of HRMA were included in the meta-analysis. We found that HRMA was a highly sensitive test for detecting disease-associated mutations in humans. Overall, the summary sensitivity was 97.5% (95% confidence interval (CI): 96.8-98.5; I(2)?=?27.0%). Subgroup analysis showed even higher sensitivity for non-HR-1 instruments (sensitivity 98.7% (95%CI: 97.7-99.3; I(2)?=?0.0%)) and an eligible sample size subgroup (sensitivity 99.3% (95%CI: 98.1-99.8; I(2)?=?0.0%)). HRMA specificity showed considerable heterogeneity between studies. Sensitivity of the techniques was influenced by sample size and instrument type but by not sample source or dye type.

Conclusions/significance

These findings show that HRMA is a highly sensitive, simple and low-cost test to detect human disease-associated mutations, especially for samples with mutations of low incidence. The burden on DNA sequencing could be significantly reduced by the implementation of HRMA, but it should be recognized that its sensitivity varies according to the number of samples with/without mutations, and positive results require DNA sequencing for confirmation.

SUBMITTER: Li BS 

PROVIDER: S-EPMC3237421 | biostudies-literature | 2011

REPOSITORIES: biostudies-literature

altmetric image

Publications

Is high resolution melting analysis (HRMA) accurate for detection of human disease-associated mutations? A meta analysis.

Li Bing-Sheng BS   Wang Xin-Ying XY   Ma Feng-Li FL   Jiang Bo B   Song Xiao-Xiao XX   Xu An-Gao AG  

PloS one 20111214 12


<h4>Background</h4>High Resolution Melting Analysis (HRMA) is becoming the preferred method for mutation detection. However, its accuracy in the individual clinical diagnostic setting is variable. To assess the diagnostic accuracy of HRMA for human mutations in comparison to DNA sequencing in different routine clinical settings, we have conducted a meta-analysis of published reports.<h4>Methodology/principal findings</h4>Out of 195 publications obtained from the initial search criteria, thirty-f  ...[more]

Similar Datasets

| S-EPMC4113452 | biostudies-literature
| S-EPMC3022009 | biostudies-literature
| S-EPMC3228712 | biostudies-literature
| S-EPMC2949603 | biostudies-literature
| S-EPMC7284048 | biostudies-literature