Design and validation of a compressive tissue stimulator with high-throughput capacity and real-time modulus measurement capability.


ABSTRACT: Mechanical stimulation has been shown to impact the properties of engineered hyaline cartilage constructs and is relevant for engineering of cartilage and osteochondral tissues. Most mechanical stimulators developed to date emphasize precision over adaptability to standard tissue culture equipment and protocols. The realization of mechanical characteristics in engineered constructs approaching native cartilage requires the optimization of complex variables (type of stimulus, regimen, and bimolecular signals). We have proposed and validated a stimulator design that focuses on high construct capacity, compatibility with tissue culture plastic ware, and regimen adaptability to maximize throughput. This design utilizes thin force sensors in lieu of a load cell and a linear encoder to verify position. The implementation of an individual force sensor for each sample enables the measurement of Young's modulus while stimulating the sample. Removable and interchangeable Teflon plungers mounted using neodymium magnets contact each sample. Variations in plunger height and design can vary the strain and force type on individual samples. This allows for the evaluation of a myriad of culture conditions and regimens simultaneously. The system was validated using contact accuracy, and Young's modulus measurements range as key parameters. Contact accuracy for the system was excellent within 1.16% error of the construct height in comparison to measurements made with a micrometer. Biomaterials ranging from bioceramics (cancellous bone, 123?MPa) to soft gels (1% agarose, 20?KPa) can be measured without any modification to the device. The accuracy of measurements in conjunction with the wide range of moduli tested demonstrate the unique characteristics of the device and the feasibility of using this device in mapping real-time changes to Young's modulus of tissue constructs (cartilage, bone) through the developmental phases in ex vivo culture conditions.

SUBMITTER: Salvetti DJ 

PROVIDER: S-EPMC3285600 | biostudies-literature | 2012 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Design and validation of a compressive tissue stimulator with high-throughput capacity and real-time modulus measurement capability.

Salvetti David J DJ   Pino Christopher J CJ   Manuel Steven G SG   Dallmeyer Ian I   Rangarajan Sanjeet V SV   Meyer Tobias T   Kotov Misha M   Shastri V Prasad VP  

Tissue engineering. Part C, Methods 20120104 3


Mechanical stimulation has been shown to impact the properties of engineered hyaline cartilage constructs and is relevant for engineering of cartilage and osteochondral tissues. Most mechanical stimulators developed to date emphasize precision over adaptability to standard tissue culture equipment and protocols. The realization of mechanical characteristics in engineered constructs approaching native cartilage requires the optimization of complex variables (type of stimulus, regimen, and bimolec  ...[more]

Similar Datasets

| S-EPMC5668273 | biostudies-literature
| S-EPMC10018569 | biostudies-literature
| S-EPMC9245063 | biostudies-literature
| S-EPMC5745777 | biostudies-literature
| S-EPMC2900255 | biostudies-literature
| S-EPMC6283901 | biostudies-literature
| S-EPMC4723153 | biostudies-literature
| S-EPMC2244704 | biostudies-literature
| S-EPMC2905370 | biostudies-literature
| S-EPMC6952787 | biostudies-literature