Unknown

Dataset Information

0

Three-dimensional noninvasive monitoring iodine-131 uptake in the thyroid using a modified Cerenkov luminescence tomography approach.


ABSTRACT:

Background

Cerenkov luminescence tomography (CLT) provides the three-dimensional (3D) radiopharmaceutical biodistribution in small living animals, which is vital to biomedical imaging. However, existing single-spectral and multispectral methods are not very efficient and effective at reconstructing the distribution of the radionuclide tracer. In this paper, we present a semi-quantitative Cerenkov radiation spectral characteristic-based source reconstruction method named the hybrid spectral CLT, to efficiently reconstruct the radionuclide tracer with both encouraging reconstruction results and less acquisition and image reconstruction time.

Methodology/principal findings

We constructed the implantation mouse model implanted with a 400 µCi Na(131)I radioactive source and the physiological mouse model received an intravenous tail injection of 400 µCi radiopharmaceutical Iodine-131 (I-131) to validate the performance of the hybrid spectral CLT and compared the reconstruction results, acquisition, and image reconstruction time with that of single-spectral and multispectral CLT. Furthermore, we performed 3D noninvasive monitoring of I-131 uptake in the thyroid and quantified I-131 uptake in vivo using hybrid spectral CLT. Results showed that the reconstruction based on the hybrid spectral CLT was more accurate in localization and quantification than using single-spectral CLT, and was more efficient in the in vivo experiment compared with multispectral CLT. Additionally, 3D visualization of longitudinal observations suggested that the reconstructed energy of I-131 uptake in the thyroid increased with acquisition time and there was a robust correlation between the reconstructed energy versus the gamma ray counts of I-131 (r(2) = 0.8240). The ex vivo biodistribution experiment further confirmed the I-131 uptake in the thyroid for hybrid spectral CLT.

Conclusions/significance

Results indicated that hybrid spectral CLT could be potentially used for thyroid imaging to evaluate its function and monitor its treatment for thyroid cancer.

SUBMITTER: Hu Z 

PROVIDER: S-EPMC3358266 | biostudies-literature | 2012

REPOSITORIES: biostudies-literature

altmetric image

Publications

Three-dimensional noninvasive monitoring iodine-131 uptake in the thyroid using a modified Cerenkov luminescence tomography approach.

Hu Zhenhua Z   Ma Xiaowei X   Qu Xiaochao X   Yang Weidong W   Liang Jimin J   Wang Jing J   Tian Jie J  

PloS one 20120522 5


<h4>Background</h4>Cerenkov luminescence tomography (CLT) provides the three-dimensional (3D) radiopharmaceutical biodistribution in small living animals, which is vital to biomedical imaging. However, existing single-spectral and multispectral methods are not very efficient and effective at reconstructing the distribution of the radionuclide tracer. In this paper, we present a semi-quantitative Cerenkov radiation spectral characteristic-based source reconstruction method named the hybrid spectr  ...[more]

Similar Datasets

2016-06-30 | GSE66623 | GEO
2016-06-30 | E-GEOD-66623 | biostudies-arrayexpress
| S-EPMC3068779 | biostudies-literature
| S-EPMC7317313 | biostudies-literature
| S-EPMC4167912 | biostudies-literature
| S-EPMC3903390 | biostudies-literature
| S-EPMC3798970 | biostudies-literature
| S-EPMC9088772 | biostudies-literature
| S-EPMC3698946 | biostudies-other
| S-EPMC5037157 | biostudies-literature