Unknown

Dataset Information

0

Label-free quantitation of protein modifications by pseudo selected reaction monitoring with internal reference peptides.


ABSTRACT: Liquid chromatography tandem mass spectrometry (LC-MS/MS) based methods provide powerful tools for the quantitative analysis of modified proteins. We have developed a label-free approach using internal reference peptides (IRP) from the target protein for signal normalization without the need for isotope labeling. Ion-trap mass spectrometry and pseudo-selected reaction monitoring (pSRM) were used to acquire full MS/MS and MS(3) spectra from target peptides. Skyline, a widely used software for SRM experiments, was used for chromatographic ion extraction. Phosphopeptides spiked into a BSA background yielded concentration response curves with high correlation coefficients (typically >0.9) and low coefficients of variation (?15%) over a 200-fold concentration range. Stable isotope dilution (SID) and IRP methods were compared for quantitation of six site-specific phosphorylations in the epidermal growth factor receptor (EGFR) in epidermal growth factor-stimulated A431 cells with or without the addition of EGFR inhibitors cetuximab and gefitinib. Equivalent responses were observed with both IRP and SID methods, although analyses using the IRP method typically had higher median CVs (22-31%) than SID (10-20%). Analyses using both methods were consistent with immunoblot using site-selective antibodies. The ease of implementation and the suitability for targeted quantitative comparisons make this method suitable for broad application in protein biochemistry.

SUBMITTER: Sherrod SD 

PROVIDER: S-EPMC3368409 | biostudies-literature | 2012 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Label-free quantitation of protein modifications by pseudo selected reaction monitoring with internal reference peptides.

Sherrod Stacy D SD   Myers Matthew V MV   Li Ming M   Myers Jeremy S JS   Carpenter Kristin L KL   Maclean Brendan B   Maccoss Michael J MJ   Liebler Daniel C DC   Ham Amy-Joan L AJ  

Journal of proteome research 20120517 6


Liquid chromatography tandem mass spectrometry (LC-MS/MS) based methods provide powerful tools for the quantitative analysis of modified proteins. We have developed a label-free approach using internal reference peptides (IRP) from the target protein for signal normalization without the need for isotope labeling. Ion-trap mass spectrometry and pseudo-selected reaction monitoring (pSRM) were used to acquire full MS/MS and MS(3) spectra from target peptides. Skyline, a widely used software for SRM  ...[more]

Similar Datasets

| S-EPMC3983013 | biostudies-literature
| S-EPMC3990191 | biostudies-literature
| S-EPMC3426189 | biostudies-literature
| S-EPMC3675810 | biostudies-literature
| S-EPMC4222624 | biostudies-literature
| S-EPMC3005404 | biostudies-literature
| S-EPMC3046293 | biostudies-literature
2017-12-11 | PXD008094 | Pride
| S-EPMC5754789 | biostudies-literature
| S-EPMC2583086 | biostudies-other