Unknown

Dataset Information

0

No evidence for interference of h&e staining in DNA testing: usefulness of DNA extraction from H&E-stained archival tissue sections.


ABSTRACT: Although histochemical staining has been believed to inhibit the DNA amplification reaction, no previous study has systematically evaluated the influence of histochemical staining on downstream molecular assays. To evaluate an influence of H&E staining on DNA testing, we isolated DNA from 10 unstained, 10 hematoxylin-stained, 10 eosin-stained, and 10 H&E-stained tissue sections (ie, 4 groups), from each of 5 colon cancers. Among the 4 groups, we did not observe any significant or appreciable difference in DNA fragmentation by agarose gel electrophoresis, in DNA amplification by real-time polymerase chain reaction (PCR), in microsatellite PCR fragment analyses, or in a PCR-pyrosequencing assay. As a proof-of-principle study, we successfully performed microsatellite instability analysis and sequencing of KRAS and BRAF on more than 1,300 colorectal cancers using DNA extracted from H&E-stained tissue sections. Our data provide no evidence for an interfering effect of H&E staining on DNA testing, suggesting that DNA from H&E-stained sections can be effectively used for routine DNA testing.

SUBMITTER: Morikawa T 

PROVIDER: S-EPMC3383644 | biostudies-literature | 2012 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

No evidence for interference of h&e staining in DNA testing: usefulness of DNA extraction from H&E-stained archival tissue sections.

Morikawa Teppei T   Shima Kaori K   Kuchiba Aya A   Yamauchi Mai M   Tanaka Noriko N   Imamura Yu Y   Liao Xiaoyun X   Qian Zhi Rong ZR   Brahmandam Mohan M   Longtine Janina A JA   Lindeman Neal I NI   Fuchs Charles S CS   Ogino Shuji S  

American journal of clinical pathology 20120701 1


Although histochemical staining has been believed to inhibit the DNA amplification reaction, no previous study has systematically evaluated the influence of histochemical staining on downstream molecular assays. To evaluate an influence of H&E staining on DNA testing, we isolated DNA from 10 unstained, 10 hematoxylin-stained, 10 eosin-stained, and 10 H&E-stained tissue sections (ie, 4 groups), from each of 5 colon cancers. Among the 4 groups, we did not observe any significant or appreciable dif  ...[more]

Similar Datasets

| S-EPMC5930952 | biostudies-literature
| S-EPMC9050807 | biostudies-literature
| S-EPMC3796308 | biostudies-literature
| S-EPMC6759515 | biostudies-literature
| S-EPMC5533273 | biostudies-other
| S-EPMC7701168 | biostudies-literature
| S-EPMC8336840 | biostudies-literature
| S-EPMC5533214 | biostudies-literature
| S-EPMC3320745 | biostudies-literature
| S-EPMC4488390 | biostudies-literature