ABSTRACT: Introduction
In a companion methodological study, we compared two anti-ZAP-70 clones (1E7.2 AF 488 and SBZAP PE) and four selected methods of analysis. Clinical correlations are required for validation.Methods
Multicolor flow-cytometric evaluation of ZAP-70, CD38, CD69, CD26, CD49d, and CD27 was tested in 45 untreated-CLL patients. Four methods of ZAP-70 expression analysis and a scoring system were designed. A correlation analysis between ZAP-70 score, immunoglobulin heavy chain variable (IGHV) mutational status, fluorescence in situ hybridization, and these biomarkers was undertaken.Results
There is a strong correlation between ZAP-70 expression and IGHV mutational status. The scoring system for a single reagent (P = 0.0006 or 0.0002) favors the use of multiple methods of analysis. The combined score was substantially equivalent (P = 0.0003). There was also a correlation with del 13q14 (P = 0.017) and trisomy12 (P = 0.011). A correlation for CD38 and ZAP-70 score was seen using both 1E7.2 AF488 and SBZAP PE when ≥20% or ≥7% cutoff was used. A positive correlation was seen for CD49d expression using both reagents. CD26 showed a correlation with ZAP-70 expression, but it was dependent upon the method of analysis. CD69 and CD27 showed no statistically significant correlation.Conclusion
In our study population, ZAP-70 expression is the better predictor of the IGHV mutational status. The correlation analysis confirms that the use of four methods of analysis with a single reagent or both reagents is superior to the use of a single method of analysis. The routine use of CD38, CD49d, and CD26 will require standardization.
SUBMITTER: Degheidy HA
PROVIDER: S-EPMC3407415 | biostudies-literature | 2011 Sep
REPOSITORIES: biostudies-literature
Degheidy Heba A HA Venzon David J DJ Farooqui Mohammed Z H MZ Abbasi Fatima F Arthur Diane C DC Wilson Wyndham H WH Wiestner Adrian A Stetler-Stevenson M A MA Marti Gerald E GE
Cytometry. Part B, Clinical cytometry 20110406 5
<h4>Introduction</h4>In a companion methodological study, we compared two anti-ZAP-70 clones (1E7.2 AF 488 and SBZAP PE) and four selected methods of analysis. Clinical correlations are required for validation.<h4>Methods</h4>Multicolor flow-cytometric evaluation of ZAP-70, CD38, CD69, CD26, CD49d, and CD27 was tested in 45 untreated-CLL patients. Four methods of ZAP-70 expression analysis and a scoring system were designed. A correlation analysis between ZAP-70 score, immunoglobulin heavy chain ...[more]