Unknown

Dataset Information

0

Improved ZAP-70 assay using two clones, multiple methods of analysis and clinical correlation.


ABSTRACT: INTRODUCTION:In a companion methodological study, we compared two anti-ZAP-70 clones (1E7.2 AF 488 and SBZAP PE) and four selected methods of analysis. Clinical correlations are required for validation. METHODS:Multicolor flow-cytometric evaluation of ZAP-70, CD38, CD69, CD26, CD49d, and CD27 was tested in 45 untreated-CLL patients. Four methods of ZAP-70 expression analysis and a scoring system were designed. A correlation analysis between ZAP-70 score, immunoglobulin heavy chain variable (IGHV) mutational status, fluorescence in situ hybridization, and these biomarkers was undertaken. RESULTS:There is a strong correlation between ZAP-70 expression and IGHV mutational status. The scoring system for a single reagent (P = 0.0006 or 0.0002) favors the use of multiple methods of analysis. The combined score was substantially equivalent (P = 0.0003). There was also a correlation with del 13q14 (P = 0.017) and trisomy12 (P = 0.011). A correlation for CD38 and ZAP-70 score was seen using both 1E7.2 AF488 and SBZAP PE when ?20% or ?7% cutoff was used. A positive correlation was seen for CD49d expression using both reagents. CD26 showed a correlation with ZAP-70 expression, but it was dependent upon the method of analysis. CD69 and CD27 showed no statistically significant correlation. CONCLUSION:In our study population, ZAP-70 expression is the better predictor of the IGHV mutational status. The correlation analysis confirms that the use of four methods of analysis with a single reagent or both reagents is superior to the use of a single method of analysis. The routine use of CD38, CD49d, and CD26 will require standardization.

SUBMITTER: Degheidy HA 

PROVIDER: S-EPMC3407415 | biostudies-literature | 2011 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improved ZAP-70 assay using two clones, multiple methods of analysis and clinical correlation.

Degheidy Heba A HA   Venzon David J DJ   Farooqui Mohammed Z H MZ   Abbasi Fatima F   Arthur Diane C DC   Wilson Wyndham H WH   Wiestner Adrian A   Stetler-Stevenson M A MA   Marti Gerald E GE  

Cytometry. Part B, Clinical cytometry 20110406 5


<h4>Introduction</h4>In a companion methodological study, we compared two anti-ZAP-70 clones (1E7.2 AF 488 and SBZAP PE) and four selected methods of analysis. Clinical correlations are required for validation.<h4>Methods</h4>Multicolor flow-cytometric evaluation of ZAP-70, CD38, CD69, CD26, CD49d, and CD27 was tested in 45 untreated-CLL patients. Four methods of ZAP-70 expression analysis and a scoring system were designed. A correlation analysis between ZAP-70 score, immunoglobulin heavy chain  ...[more]

Similar Datasets

| S-EPMC3461319 | biostudies-literature
2006-09-22 | GSE4392 | GEO
| S-EPMC7214800 | biostudies-literature
2009-04-23 | E-GEOD-4392 | biostudies-arrayexpress
| S-EPMC2857167 | biostudies-literature
| S-EPMC3407416 | biostudies-literature
| S-EPMC1180533 | biostudies-literature
| S-EPMC2118636 | biostudies-literature
| S-EPMC2323614 | biostudies-other
| S-EPMC4902731 | biostudies-literature