Chip-based nLC-TOF-MS is a highly stable technology for large-scale high-throughput analyses.


ABSTRACT: Many studies focused on the discovery of novel biomarkers for the diagnosis and treatment of disease states are facilitated by mass spectrometry-based technology. HPLC coupled to mass spectrometry is widely used; miniaturization of this technique using nano-liquid chromatography (LC)-mass spectrometry (MS) usually results in better sensitivity, but is associated with limited repeatability. The recent introduction of chip-based technology has significantly improved the stability of nano-LC-MS, but no substantial studies to verify this have been performed. To evaluate the temporal repeatability of chip-based nano-LC-MS analyses, N-glycans released from a serum sample were repeatedly analyzed using nLC-PGC-chip-TOF-MS on three non-consecutive days. With an average inter-day coefficient of variation of 4 %, determined on log10-transformed integrals, the repeatability of the system is very high. Overall, chip-based nano-LC-MS appears to be a highly stable technology, which is suitable for the profiling of large numbers of clinical samples for biomarker discovery.

SUBMITTER: Ruhaak LR 

PROVIDER: S-EPMC3640767 | biostudies-literature | 2013 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Chip-based nLC-TOF-MS is a highly stable technology for large-scale high-throughput analyses.

Ruhaak L Renee LR   Taylor Sandra L SL   Miyamoto Suzanne S   Kelly Karen K   Leiserowitz Gary S GS   Gandara David D   Lebrilla Carlito B CB   Kim Kyoungmi K  

Analytical and bioanalytical chemistry 20130323 14


Many studies focused on the discovery of novel biomarkers for the diagnosis and treatment of disease states are facilitated by mass spectrometry-based technology. HPLC coupled to mass spectrometry is widely used; miniaturization of this technique using nano-liquid chromatography (LC)-mass spectrometry (MS) usually results in better sensitivity, but is associated with limited repeatability. The recent introduction of chip-based technology has significantly improved the stability of nano-LC-MS, bu  ...[more]

Similar Datasets

| S-EPMC6857025 | biostudies-literature
| S-EPMC5066972 | biostudies-literature
| S-EPMC6271863 | biostudies-other
| S-EPMC4831011 | biostudies-literature
| S-EPMC4332152 | biostudies-literature
| S-EPMC8216829 | biostudies-literature
| S-EPMC6946754 | biostudies-literature
| S-EPMC7001660 | biostudies-literature
| S-EPMC3395638 | biostudies-literature
| S-EPMC6918290 | biostudies-literature