Highly sensitive detection of hepatitis B virus surface antigen by use of a semiautomated immune complex transfer chemiluminescence enzyme immunoassay.


ABSTRACT: The performance of hepatitis B surface antigen (HBsAg) screening assays is continuously improved to reduce the risk of transfusion-associated hepatitis B. In this study, a semiautomated immune complex transfer chemiluminescence enzyme immunoassay (ICT-CLEIA) for the detection of HBsAg, which is as sensitive as hepatitis B virus (HBV) DNA PCR, was developed; the ICT-CLEIA assay performance was compared with the performance of the Architect HBsAg QT assay and HBV DNA PCR. The specificities in the initial assay and after retesting were 99.50% (1,988/1,998 samples) and 99.95% (1,997/1,998 samples), respectively. The analytical detection limit was determined to be 0.2 mIU/ml using the 2nd International WHO HBsAg standard, and the cutoff value (0.5 mIU/ml) of the ICT-CLEIA assay was 8.0 standard deviations (SD) above the mean of the HBsAg-negative specimens. The ICT-CLEIA assay could detect HBsAg even in the presence of anti-HBs antibodies and demonstrated a 23.6-day-shorter window period using commercially available HBsAg seroconversion panels than the Architect HBsAg QT assay. Furthermore, the monitoring of the viral kinetics by the ICT-CLEIA assay and the HBV DNA PCR produced very similarly shaped curves during both the HBsAg seroconversion and reverse seroconversion periods. Therefore, the ICT-CLEIA assay may be useful not only for an earlier detection of HBV reactivation but also for the monitoring of hepatitis B patients.

SUBMITTER: Takeda K 

PROVIDER: S-EPMC3697675 | biostudies-literature | 2013 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Highly sensitive detection of hepatitis B virus surface antigen by use of a semiautomated immune complex transfer chemiluminescence enzyme immunoassay.

Takeda Kazuhiko K   Maruki Mari M   Yamagaito Takahiro T   Muramatsu Machiko M   Sakai Yasuhiro Y   Tobimatsu Hiroaki H   Kobayashi Hironori H   Mizuno Yoshiteru Y   Hamaguchi Yukio Y  

Journal of clinical microbiology 20130508 7


The performance of hepatitis B surface antigen (HBsAg) screening assays is continuously improved to reduce the risk of transfusion-associated hepatitis B. In this study, a semiautomated immune complex transfer chemiluminescence enzyme immunoassay (ICT-CLEIA) for the detection of HBsAg, which is as sensitive as hepatitis B virus (HBV) DNA PCR, was developed; the ICT-CLEIA assay performance was compared with the performance of the Architect HBsAg QT assay and HBV DNA PCR. The specificities in the  ...[more]

Similar Datasets

| S-EPMC84955 | biostudies-literature
| S-EPMC7813740 | biostudies-literature
| S-EPMC6817178 | biostudies-literature
| S-EPMC9718149 | biostudies-literature
| S-EPMC6765353 | biostudies-literature
| S-EPMC5908853 | biostudies-literature
| S-EPMC8440549 | biostudies-literature
| S-EPMC1152485 | biostudies-other
| S-EPMC6873229 | biostudies-literature
| S-EPMC3517206 | biostudies-literature