A microfluidic localized, multiple cell culture array using vacuum actuated cell seeding: integrated anticancer drug testing.


ABSTRACT: In this study, we introduced a novel and convenient approach to culture multiple cells in localized arrays of microfluidic chambers using one-step vacuum actuation. In one device, we integrated 8 individually addressable regions of culture chambers, each only requiring one simple vacuum operation to seed cell lines. Four cell lines were seeded in designated regions in one device via sequential injection with high purity (99.9 %-100 %) and cultured for long-term. The on-chip simultaneous culture of HuT 78, Ramos, PC-3 and C166-GFP cells for 48 h was demonstrated with viabilities of 92 %+/-2 %, 94 %+/-4 %, 96 %+/-2 % and 97 %+/-2 %, respectively. The longest culture period for C166-GFP cells in this study was 168 h with a viability of 96 %+/-10 %. Cell proliferation in each individual side channel can be tracked. Mass transport between the main channel and side channels was achieved through diffusion and studied using fluorescein solution. The main advantage of this device is the capability to perform multiple cell-based assays on the same device for better comparative studies. After treating cells with staurosporine or anti-human CD95 for 16 h, the apoptotic cell percentage of HuT 78, CCRF-CEM, PC-3 and Ramos cells were 36 %+/-3 %, 24 %+/-4 %, 12 %+/-2 %, 18 %+/-4 % for staurosporine, and 63 %+/-2 %, 45 %+/-1 %, 3 %+/-3 %, 27 %+/-12 % for anti-human CD95, respectively. With the advantages of enhanced integration, ease of use and fabrication, and flexibility, this device will be suitable for long-term multiple cell monitoring and cell based assays.

SUBMITTER: Gao Y 

PROVIDER: S-EPMC3830671 | biostudies-literature | 2013 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

A microfluidic localized, multiple cell culture array using vacuum actuated cell seeding: integrated anticancer drug testing.

Gao Yan Y   Li Peng P   Pappas Dimitri D  

Biomedical microdevices 20131201 6


In this study, we introduced a novel and convenient approach to culture multiple cells in localized arrays of microfluidic chambers using one-step vacuum actuation. In one device, we integrated 8 individually addressable regions of culture chambers, each only requiring one simple vacuum operation to seed cell lines. Four cell lines were seeded in designated regions in one device via sequential injection with high purity (99.9 %-100 %) and cultured for long-term. The on-chip simultaneous culture  ...[more]

Similar Datasets

| S-EPMC5073376 | biostudies-literature
| S-EPMC3510264 | biostudies-other
| S-EPMC2071914 | biostudies-literature
| S-EPMC8066247 | biostudies-literature
| S-EPMC4073611 | biostudies-literature
| S-EPMC8699815 | biostudies-literature
| S-EPMC6632054 | biostudies-literature
| S-EPMC6049921 | biostudies-literature
| S-EPMC4143330 | biostudies-other
| S-EPMC3365332 | biostudies-other