Unknown

Dataset Information

0

Comparison of protein immunoprecipitation-multiple reaction monitoring with ELISA for assay of biomarker candidates in plasma.


ABSTRACT: Quantitative analysis of protein biomarkers in plasma is typically done by ELISA, but this method is limited by the availability of high-quality antibodies. An alternative approach is protein immunoprecipitation combined with multiple reaction monitoring mass spectrometry (IP-MRM). We compared IP-MRM to ELISA for the analysis of six colon cancer biomarker candidates (metalloproteinase inhibitor 1 (TIMP1), cartilage oligomeric matrix protein (COMP), thrombospondin-2 (THBS2), endoglin (ENG), mesothelin (MSLN) and matrix metalloproteinase-9 (MMP9)) in plasma from colon cancer patients and noncancer controls. Proteins were analyzed by multiplex immunoprecipitation from plasma with the ELISA capture antibodies, further purified by SDS-PAGE, digested and analyzed by stable isotope dilution MRM. IP-MRM provided linear responses (r = 0.978-0.995) between 10 and 640 ng/mL for the target proteins spiked into a "mock plasma" matrix consisting of 60 mg/mL bovine serum albumin. Measurement variation (coefficient of variation at the limit of detection) for IP-MRM assays ranged from 2.3 to 19%, which was similar to variation for ELISAs of the same samples. IP-MRM and ELISA measurements for all target proteins except ENG were highly correlated (r = 0.67-0.97). IP-MRM with high-quality capture antibodies thus provides an effective alternative method to ELISA for protein quantitation in biological fluids.

SUBMITTER: Lin D 

PROVIDER: S-EPMC3864264 | biostudies-literature | 2013 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of protein immunoprecipitation-multiple reaction monitoring with ELISA for assay of biomarker candidates in plasma.

Lin De D   Alborn William E WE   Slebos Robbert J C RJ   Liebler Daniel C DC  

Journal of proteome research 20131119 12


Quantitative analysis of protein biomarkers in plasma is typically done by ELISA, but this method is limited by the availability of high-quality antibodies. An alternative approach is protein immunoprecipitation combined with multiple reaction monitoring mass spectrometry (IP-MRM). We compared IP-MRM to ELISA for the analysis of six colon cancer biomarker candidates (metalloproteinase inhibitor 1 (TIMP1), cartilage oligomeric matrix protein (COMP), thrombospondin-2 (THBS2), endoglin (ENG), mesot  ...[more]

Similar Datasets

| S-EPMC8786819 | biostudies-literature
| S-EPMC2984228 | biostudies-literature
| S-EPMC4584066 | biostudies-literature
| S-EPMC2722777 | biostudies-literature
| S-EPMC6933034 | biostudies-literature
| S-EPMC6123701 | biostudies-literature
| S-EPMC7347090 | biostudies-literature
| S-EPMC6425740 | biostudies-literature
2021-09-09 | PXD022756 | Pride
| S-EPMC5407814 | biostudies-other