Unknown

Dataset Information

0

A quantitative determination of magnetic nanoparticle separation using on-off field operation of quadrupole magnetic field-flow fractionation (QMgFFF).


ABSTRACT: Quadrupole Magnetic Field-Flow Fractionation (QMgFFF) is a technique for characterization of sub-micrometer magnetic particles based on their retention in the magnetic field from flowing suspensions. Different magnetic field strengths and volumetric flow rates were tested using on-off field application and two commercial nanoparticle preparations that significantly differed in their retention parameter, ? (by nearly 8-fold). The fractograms showed a regular pattern of higher retention (98.6% v. 53.3%) for the larger particle (200 nm v. 90 nm) at the higher flow rate (0.05 mL/min v. 0.01 mL/min) at the highest magnetic field (0.52 T), as expected because of its lower retention parameter. The significance of this approach is a demonstration of a system that is simpler in operation than a programmed field QMgFFF in applications to particle mixtures consisting of two distinct particle fractions. This approach could be useful for detection of unwanted particulate contaminants, especially important in industrial and biomedical applications.

SUBMITTER: Orita T 

PROVIDER: S-EPMC3919639 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

altmetric image

Publications

A quantitative determination of magnetic nanoparticle separation using on-off field operation of quadrupole magnetic field-flow fractionation (QMgFFF).

Orita Toru T   Moore Lee R LR   Joshi Powrnima P   Tomita Masahiro M   Horiuchi Takashi T   Zborowski Maciej M  

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 20130101 7


Quadrupole Magnetic Field-Flow Fractionation (QMgFFF) is a technique for characterization of sub-micrometer magnetic particles based on their retention in the magnetic field from flowing suspensions. Different magnetic field strengths and volumetric flow rates were tested using on-off field application and two commercial nanoparticle preparations that significantly differed in their retention parameter, λ (by nearly 8-fold). The fractograms showed a regular pattern of higher retention (98.6% v.  ...[more]

Similar Datasets

| S-EPMC4510429 | biostudies-literature
| S-EPMC7735732 | biostudies-literature
| S-EPMC3815437 | biostudies-literature
| S-EPMC6057617 | biostudies-literature
| S-EPMC6733524 | biostudies-literature
| S-EPMC9988405 | biostudies-literature
| S-EPMC7340584 | biostudies-literature
| S-EPMC3364835 | biostudies-other
| S-EPMC6459789 | biostudies-literature
| S-EPMC6451313 | biostudies-literature