Self-cleaning membrane to extend the lifetime of an implanted glucose biosensor.


ABSTRACT: The lifetime and efficacy of a subcutaneously implanted glucose biosensor could be greatly improved by a self-cleaning membrane capable of periodic physical removal of adhered cells associated with the foreign body reaction. Previously, we reported a thermoresponsive double network nanocomposite (DNNC) membrane composed of poly(N-isopropylacrylamide) (PNIPAAm) and embedded polysiloxane nanoparticles. When the membrane was thermally cycled above and below its volume phase transition temperature (VPTT, ~33-35 °C), the associated deswelling and reswelling, respectively, led to in vitro cell release. Herein, this membrane design was tailored to meet the specific demands of a subcutaneously implanted glucose biosensor, and critical functional properties were assessed. First, N-vinylpyrrolidone (NVP) comonomer increased the VPTT to ~38 °C so that the membrane would be swollen and thus more permeable to glucose in the "off-state" (i.e., no heating) while residing in the subcutaneous tissue (~35 °C). Second, glucose diffusion kinetics though the DNNC membrane was experimentally measured in its deswollen and reswollen states. A cylindrical DNNC membrane with dimensions considered suitable for implantation (1.5 × 5 mm, diameter × length) was used to model the glucose diffusion lag time. In addition, the DNNC cylinder was used to observe dimensional changes associated with deswelling and reswelling. Noncytotoxicity was confirmed and self-cleaning was assessed in vitro in terms of thermally driven cell release to confirm the potential of the DNNC membrane to control biofouling.

SUBMITTER: Abraham AA 

PROVIDER: S-EPMC3927323 | biostudies-literature | 2013 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Self-cleaning membrane to extend the lifetime of an implanted glucose biosensor.

Abraham Alexander A AA   Fei Ruochong R   Coté Gerard L GL   Grunlan Melissa A MA  

ACS applied materials & interfaces 20131211 24


The lifetime and efficacy of a subcutaneously implanted glucose biosensor could be greatly improved by a self-cleaning membrane capable of periodic physical removal of adhered cells associated with the foreign body reaction. Previously, we reported a thermoresponsive double network nanocomposite (DNNC) membrane composed of poly(N-isopropylacrylamide) (PNIPAAm) and embedded polysiloxane nanoparticles. When the membrane was thermally cycled above and below its volume phase transition temperature (  ...[more]

Similar Datasets

| S-EPMC6801115 | biostudies-literature
| S-EPMC5438207 | biostudies-literature
| S-EPMC6988489 | biostudies-literature
| S-EPMC9067432 | biostudies-literature
| S-EPMC9920405 | biostudies-literature
| S-EPMC2769691 | biostudies-literature
| S-EPMC5547077 | biostudies-literature
| S-EPMC7825672 | biostudies-literature
| S-EPMC2864295 | biostudies-literature
| S-EPMC6256853 | biostudies-literature