Unknown

Dataset Information

0

D3, the new diffractometer for the macromolecular crystallography beamlines of the Swiss Light Source.


ABSTRACT: A new diffractometer for microcrystallography has been developed for the three macromolecular crystallography beamlines of the Swiss Light Source. Building upon and critically extending previous developments realised for the high-resolution endstations of the two undulator beamlines X06SA and X10SA, as well as the super-bend dipole beamline X06DA, the new diffractometer was designed to the following core design goals. (i) Redesign of the goniometer to a sub-micrometer peak-to-peak cylinder of confusion for the horizontal single axis. Crystal sizes down to at least 5?µm and advanced sample-rastering and scanning modes are supported. In addition, it can accommodate the new multi-axis goniometer PRIGo (Parallel Robotics Inspired Goniometer). (ii) A rapid-change beam-shaping element system with aperture sizes down to a minimum of 10?µm for microcrystallography measurements. (iii) Integration of the on-axis microspectrophotometer MS3 for microscopic sample imaging with 1?µm image resolution. Its multi-mode optical spectroscopy module is always online and supports in situ UV/Vis absorption, fluorescence and Raman spectroscopy. (iv) High stability of the sample environment by a mineral cast support construction and by close containment of the cryo-stream. Further features are the support for in situ crystallization plate screening and a minimal achievable detector distance of 120?mm for the Pilatus 6M, 2M and the macromolecular crystallography group's planned future area detector Eiger 16M.

SUBMITTER: Fuchs MR 

PROVIDER: S-EPMC3945418 | biostudies-literature | 2014 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications


A new diffractometer for microcrystallography has been developed for the three macromolecular crystallography beamlines of the Swiss Light Source. Building upon and critically extending previous developments realised for the high-resolution endstations of the two undulator beamlines X06SA and X10SA, as well as the super-bend dipole beamline X06DA, the new diffractometer was designed to the following core design goals. (i) Redesign of the goniometer to a sub-micrometer peak-to-peak cylinder of co  ...[more]

Similar Datasets

| S-EPMC9070724 | biostudies-literature
| S-EPMC3004250 | biostudies-literature
| S-EPMC4631482 | biostudies-literature
| S-EPMC7008514 | biostudies-literature
| S-EPMC3133520 | biostudies-other
| S-EPMC4815877 | biostudies-literature
| S-EPMC4304682 | biostudies-literature
| S-EPMC3547225 | biostudies-literature
| S-EPMC5182030 | biostudies-literature
| S-EPMC2967422 | biostudies-literature