Development of SPACE-II for rapid sample exchange at SPring-8 macromolecular crystallography beamlines.


ABSTRACT: Reducing the sample-exchange time is a crucial issue in maximizing the throughput of macromolecular crystallography (MX) beamlines because the diffraction data collection itself is completed within a minute in the era of pixel-array detectors. To this end, an upgraded sample changer, SPACE-II, has been developed on the basis of the previous model, SPACE (SPring-8 Precise Automatic Cryo-sample Exchanger), at the BL41XU beamline at SPring-8. SPACE-II achieves one sample-exchange step within 16?s, of which its action accounts for only 11?s, because of three features: (i) the implementation of twin arms that enable samples to be exchanged in one cycle of mount-arm action, (ii) the implementation of long-stroke mount arms that allow samples to be exchanged without withdrawal of the detector and (iii) the use of a fast-moving translation and rotation stage for the mount arms. By pre-holding the next sample prior to the sample-exchange sequence, the time was further decreased to 11?s in the case of automatic data collection, of which the action of SPACE-II accounted for 8?s. Moreover, the sample capacity was expanded from four to eight Uni-Pucks. The performance of SPACE-II has been demonstrated in over two years of operation at BL41XU; the average number of samples mounted on the diffractometer in one day was increased from 132 to 185, with an error rate of 0.089%, which counted incidents in which users could not continue with an experiment without recovery work by entering the experimental hutch. On the basis of these results, SPACE-II has been installed at three other MX beamlines at SPring-8 as of July 2019. The fast and highly reliable SPACE-II is now one of the most important pieces of infrastructure for the MX beamlines at SPring-8, providing users with the opportunity to fully make use of limited beamtime with brilliant X-rays.

SUBMITTER: Murakami H 

PROVIDER: S-EPMC7008514 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of SPACE-II for rapid sample exchange at SPring-8 macromolecular crystallography beamlines.

Murakami Hironori H   Hasegawa Kazuya K   Ueno Go G   Yagi Naoto N   Yamamoto Masaki M   Kumasaka Takashi T  

Acta crystallographica. Section D, Structural biology 20200131 Pt 2


Reducing the sample-exchange time is a crucial issue in maximizing the throughput of macromolecular crystallography (MX) beamlines because the diffraction data collection itself is completed within a minute in the era of pixel-array detectors. To this end, an upgraded sample changer, SPACE-II, has been developed on the basis of the previous model, SPACE (SPring-8 Precise Automatic Cryo-sample Exchanger), at the BL41XU beamline at SPring-8. SPACE-II achieves one sample-exchange step within 16 s,  ...[more]

Similar Datasets

| S-EPMC4815877 | biostudies-literature
| S-EPMC4631482 | biostudies-literature
| S-EPMC3945418 | biostudies-literature
| S-EPMC3004250 | biostudies-literature
| S-EPMC3133520 | biostudies-other
| S-EPMC7285676 | biostudies-literature
| S-EPMC4304682 | biostudies-literature
| S-EPMC5633908 | biostudies-other
| S-EPMC6712007 | biostudies-literature
| S-EPMC4973212 | biostudies-literature