Comparison between culture and a multiplex quantitative real-time polymerase chain reaction assay detecting Ureaplasma urealyticum and U. parvum.


ABSTRACT: A novel multiplex quantitative real-time polymerase chain reaction (qPCR) for simultaneous detection of U. urealyticum and U. parvum was developed and compared with quantitative culture in Shepard's 10 C medium for ureaplasmas in urethral swabs from 129 men and 66 women, and cervical swabs from 61 women. Using culture as the gold standard, the sensitivity of the qPCR was 96% and 95% for female urethral and cervical swabs, respectively. In male urethral swabs the sensitivity was 89%. The corresponding specificities were 100%, 87% and 99%. The qPCR showed a linear increasing DNA copy number with increasing colour-changing units. Although slightly less sensitive than culture, this multiplex qPCR assay detecting U. urealyticum and U. parvum constitutes a simple and fast alternative to the traditional methods for identification of ureaplasmas and allows simultaneous species differentiation and quantitation in clinical samples. Furthermore, specimens overgrown by other bacteria using the culture method can be evaluated in the qPCR.

SUBMITTER: Frolund M 

PROVIDER: S-EPMC4105565 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison between culture and a multiplex quantitative real-time polymerase chain reaction assay detecting Ureaplasma urealyticum and U. parvum.

Frølund Maria M   Björnelius Eva E   Lidbrink Peter P   Ahrens Peter P   Jensen Jørgen Skov JS  

PloS one 20140721 7


A novel multiplex quantitative real-time polymerase chain reaction (qPCR) for simultaneous detection of U. urealyticum and U. parvum was developed and compared with quantitative culture in Shepard's 10 C medium for ureaplasmas in urethral swabs from 129 men and 66 women, and cervical swabs from 61 women. Using culture as the gold standard, the sensitivity of the qPCR was 96% and 95% for female urethral and cervical swabs, respectively. In male urethral swabs the sensitivity was 89%. The correspo  ...[more]

Similar Datasets

| S-EPMC4745450 | biostudies-literature
| S-EPMC3511179 | biostudies-literature
| S-EPMC263571 | biostudies-other
| S-EPMC154667 | biostudies-literature
| S-EPMC1679810 | biostudies-literature
| S-EPMC7428672 | biostudies-literature
| S-EPMC1888491 | biostudies-literature
| S-EPMC10488090 | biostudies-literature
| S-EPMC2597193 | biostudies-literature
| S-EPMC4560903 | biostudies-literature