Unknown

Dataset Information

0

Whole body center of mass estimation with portable sensors: using the statically equivalent serial chain and a Kinect.


ABSTRACT: The trajectory of the whole body center of mass (CoM) is useful as a reliable metric of postural stability. If the evaluation of a subject-specific CoM were available outside of the laboratory environment, it would improve the assessment of the effects of physical rehabilitation. This paper develops a method that enables tracking CoM position using low-cost sensors that can be moved around by a therapist or easily installed inside a patient's home. Here, we compare the accuracy of a personalized CoM estimation using the statically equivalent serial chain (SESC) method and measurements obtained with the Kinect to the case of a SESC obtained with high-end equipment (Vicon). We also compare these estimates to literature-based ones for both sensors. The method was validated with seven able-bodied volunteers for whom the SESC was identified using 40 static postures. The literature-based estimation with Vicon measurements had a average error 24.9 ± 3.7 mm; this error was reduced to 12.8 ± 9.1 mm with the SESC identification. When using Kinect measurements, the literature-based estimate had an error of 118.4 ± 50.0 mm, while the SESC error was 26.6 ± 6.0 mm. The subject-specific SESC estimate using low-cost sensors has an equivalent performance as the literature-based one with high-end sensors. The SESC method can improve CoM estimation of elderly and neurologically impaired subjects by considering variations in their mass distribution.

SUBMITTER: Gonzalez A 

PROVIDER: S-EPMC4208208 | biostudies-literature | 2014 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Whole body center of mass estimation with portable sensors: using the statically equivalent serial chain and a Kinect.

González Alejandro A   Hayashibe Mitsuhiro M   Bonnet Vincent V   Fraisse Philippe P  

Sensors (Basel, Switzerland) 20140911 9


The trajectory of the whole body center of mass (CoM) is useful as a reliable metric of postural stability. If the evaluation of a subject-specific CoM were available outside of the laboratory environment, it would improve the assessment of the effects of physical rehabilitation. This paper develops a method that enables tracking CoM position using low-cost sensors that can be moved around by a therapist or easily installed inside a patient's home. Here, we compare the accuracy of a personalized  ...[more]

Similar Datasets

| S-EPMC10439293 | biostudies-literature
| S-EPMC7085587 | biostudies-literature
| S-EPMC6806340 | biostudies-literature
| S-EPMC10896405 | biostudies-literature
| S-EPMC7968842 | biostudies-literature
| S-EPMC5191118 | biostudies-literature
| S-EPMC7764933 | biostudies-literature
| PRJNA87987 | ENA
| S-EPMC6920470 | biostudies-literature
| S-EPMC6690400 | biostudies-literature