Unknown

Dataset Information

0

An automated system using spatial oversampling for optical mapping in murine atria. Development and validation with monophasic and transmembrane action potentials.


ABSTRACT: We developed and validated a new optical mapping system for quantification of electrical activation and repolarisation in murine atria. The system makes use of a novel 2nd generation complementary metal-oxide-semiconductor (CMOS) camera with deliberate oversampling to allow both assessment of electrical activation with high spatial and temporal resolution (128 × 2048 pixels) and reliable assessment of atrial murine repolarisation using post-processing of signals. Optical recordings were taken from isolated, superfused and electrically stimulated murine left atria. The system reliably describes activation sequences, identifies areas of functional block, and allows quantification of conduction velocities and vectors. Furthermore, the system records murine atrial action potentials with comparable duration to both monophasic and transmembrane action potentials in murine atria.

SUBMITTER: Yu TY 

PROVIDER: S-EPMC4210664 | biostudies-literature | 2014 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

An automated system using spatial oversampling for optical mapping in murine atria. Development and validation with monophasic and transmembrane action potentials.

Yu Ting Yue TY   Syeda Fahima F   Holmes Andrew P AP   Osborne Benjamin B   Dehghani Hamid H   Brain Keith L KL   Kirchhof Paulus P   Fabritz Larissa L  

Progress in biophysics and molecular biology 20140815 2-3


We developed and validated a new optical mapping system for quantification of electrical activation and repolarisation in murine atria. The system makes use of a novel 2nd generation complementary metal-oxide-semiconductor (CMOS) camera with deliberate oversampling to allow both assessment of electrical activation with high spatial and temporal resolution (128 × 2048 pixels) and reliable assessment of atrial murine repolarisation using post-processing of signals. Optical recordings were taken fr  ...[more]

Similar Datasets

| S-EPMC5613960 | biostudies-literature
| S-EPMC5779667 | biostudies-literature
| S-EPMC4137261 | biostudies-literature
| S-EPMC3248630 | biostudies-literature
| S-EPMC5150388 | biostudies-literature
| S-EPMC7607254 | biostudies-literature
| S-EPMC8433144 | biostudies-literature
| S-EPMC5883619 | biostudies-literature
| S-EPMC5165275 | biostudies-literature
| S-EPMC8564419 | biostudies-literature