Unknown

Dataset Information

0

Evaluation of a novel nicotine inhaler device: part 1--arterial and venous pharmacokinetics.


ABSTRACT: In the United Kingdom, licensed nicotine-containing products can be recommended to reduce the harm associated with smoking. Many smokers find currently available nicotine replacement products unsatisfactory. The arterial and venous pharmacokinetics (PK) of nicotine delivered via a novel inhaler device were determined.Results are reported for Parts A (N = 18) and C (N = 18) of a 4-part (A-D) Phase I study. Participants (18-55 years, ? 10 cigarettes/day, smoking within 1 hr of waking, expired carbon monoxide >10 ppm on screening) orally inhaled 2 single doses of nicotine (2 of 3 dose levels [0.22, 0.45, and 0.67 mg]) (Part A) and repeated hourly doses of 0.67 mg nicotine for 12 hr (Part C), via the novel device. Arterial and venous PK and tolerability were assessed.In Part A, mean arterial plasma nicotine concentrations at 2 min after the start of inhalation were 1.10, 2.06, and 2.59 ng/mL for the 0.22, 0.45, and 0.67 mg doses, respectively. Mean maximum arterial plasma nicotine concentrations (C(max)) were 2.11, 3.73, and 4.38 ng/mL and mean times to C(max) were 10.2, 7.3, and 6.5 min after the start of inhalation for the 0.22, 0.45, and 0.67 mg doses, respectively. In Part C, the mean pre- and postdose venous plasma nicotine concentration increased steadily and fluctuated in the range 8-10 mg/mL after 9 hr. The novel device was well tolerated; most adverse events were mild.The novel inhaler device delivers nicotine rapidly into the systemic circulation and offers a viable alternative to cigarettes for those finding it difficult to quit the behavioral and sensorial aspects of smoking.

SUBMITTER: Moyses C 

PROVIDER: S-EPMC4282122 | biostudies-literature | 2015 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of a novel nicotine inhaler device: part 1--arterial and venous pharmacokinetics.

Moyses Chris C   Hearn Alex A   Redfern Andrew A  

Nicotine & tobacco research : official journal of the Society for Research on Nicotine and Tobacco 20141110 1


<h4>Introduction</h4>In the United Kingdom, licensed nicotine-containing products can be recommended to reduce the harm associated with smoking. Many smokers find currently available nicotine replacement products unsatisfactory. The arterial and venous pharmacokinetics (PK) of nicotine delivered via a novel inhaler device were determined.<h4>Methods</h4>Results are reported for Parts A (N = 18) and C (N = 18) of a 4-part (A-D) Phase I study. Participants (18-55 years, ≥ 10 cigarettes/day, smokin  ...[more]

Similar Datasets

| S-EPMC4282120 | biostudies-other
| S-EPMC5896440 | biostudies-literature
| S-EPMC7877848 | biostudies-literature
| S-EPMC5098172 | biostudies-literature
2022-10-12 | PXD036326 | Pride
| S-EPMC3743756 | biostudies-literature
| S-EPMC7829465 | biostudies-literature
| S-EPMC8984635 | biostudies-literature
| S-EPMC10235118 | biostudies-literature
| S-EPMC3161942 | biostudies-literature