Determination of the second virial coefficient of bovine serum albumin under varying pH and ionic strength by composition-gradient multi-angle static light scattering.


ABSTRACT: Composition-gradient multi-angle static light scattering (CG-MALS) is an emerging technique for the determination of intermolecular interactions via the second virial coefficient B22. With CG-MALS, detailed studies of the second virial coefficient can be carried out more accurately and effectively than with traditional methods. In addition, automated mixing, delivery and measurement enable high speed, continuous, fluctuation-free sample delivery and accurate results. Using CG-MALS we measure the second virial coefficient of bovine serum albumin (BSA) in aqueous solutions at various values of pH and ionic strength of a univalent salt (NaCl). The systematic variation of the second virial coefficient as a function of pH and NaCl strength reveals the net charge change and the isoelectric point of BSA under different solution conditions. The magnitude of the second virial coefficient decreases to 1.13 x 10(-5) ml*mol/g(2) near the isoelectric point of pH 4.6 and 25 mM NaCl. These results illuminate the role of fundamental long-range electrostatic and van der Waals forces in protein-protein interactions, specifically their dependence on pH and ionic strength.

SUBMITTER: Ma Y 

PROVIDER: S-EPMC4298003 | biostudies-literature | 2015 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Determination of the second virial coefficient of bovine serum albumin under varying pH and ionic strength by composition-gradient multi-angle static light scattering.

Ma Yingfang Y   Acosta Diana M DM   Whitney Jon R JR   Podgornik Rudolf R   Steinmetz Nicole F NF   French Roger H RH   Parsegian V Adrian VA  

Journal of biological physics 20141118 1


Composition-gradient multi-angle static light scattering (CG-MALS) is an emerging technique for the determination of intermolecular interactions via the second virial coefficient B22. With CG-MALS, detailed studies of the second virial coefficient can be carried out more accurately and effectively than with traditional methods. In addition, automated mixing, delivery and measurement enable high speed, continuous, fluctuation-free sample delivery and accurate results. Using CG-MALS we measure the  ...[more]

Similar Datasets

| S-EPMC4014317 | biostudies-literature
| S-EPMC4251601 | biostudies-literature
| S-EPMC5036667 | biostudies-literature
| S-EPMC8510860 | biostudies-literature
| S-EPMC3766398 | biostudies-literature
| S-EPMC7308280 | biostudies-literature
| S-EPMC3641708 | biostudies-literature
| S-EPMC2908045 | biostudies-literature
| S-EPMC3605742 | biostudies-literature
| S-EPMC5055851 | biostudies-literature