A system and method for online high-resolution mapping of gastric slow-wave activity.


ABSTRACT: High-resolution (HR) mapping employs multielectrode arrays to achieve spatially detailed analyses of propagating bioelectrical events. A major current limitation is that spatial analyses must currently be performed "off-line" (after experiments), compromising timely recording feedback and restricting experimental interventions. These problems motivated development of a system and method for "online" HR mapping. HR gastric recordings were acquired and streamed to a novel software client. Algorithms were devised to filter data, identify slow-wave events, eliminate corrupt channels, and cluster activation events. A graphical user interface animated data and plotted electrograms and maps. Results were compared against off-line methods. The online system analyzed 256-channel serosal recordings with no unexpected system terminations with a mean delay 18 s. Activation time marking sensitivity was 0.92; positive predictive value was 0.93. Abnormal slow-wave patterns including conduction blocks, ectopic pacemaking, and colliding wave fronts were reliably identified. Compared to traditional analysis methods, online mapping had comparable results with equivalent coverage of 90% of electrodes, average RMS errors of less than 1 s, and CC of activation maps of 0.99. Accurate slow-wave mapping was achieved in near real-time, enabling monitoring of recording quality and experimental interventions targeted to dysrhythmic onset. This work also advances the translation of HR mapping toward real-time clinical application.

SUBMITTER: Bull SH 

PROVIDER: S-EPMC4323276 | biostudies-literature | 2014 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

A system and method for online high-resolution mapping of gastric slow-wave activity.

Bull Simon H SH   O'Grady Gregory G   Du Peng P   Cheng Leo K LK  

IEEE transactions on bio-medical engineering 20140520 11


High-resolution (HR) mapping employs multielectrode arrays to achieve spatially detailed analyses of propagating bioelectrical events. A major current limitation is that spatial analyses must currently be performed "off-line" (after experiments), compromising timely recording feedback and restricting experimental interventions. These problems motivated development of a system and method for "online" HR mapping. HR gastric recordings were acquired and streamed to a novel software client. Algorith  ...[more]

Similar Datasets

| S-EPMC5292208 | biostudies-literature
| S-EPMC6724537 | biostudies-literature
| S-EPMC3644654 | biostudies-literature
| S-EPMC3429650 | biostudies-literature
| S-EPMC4127312 | biostudies-literature
| S-EPMC3156377 | biostudies-literature
| S-EPMC4598186 | biostudies-literature
| S-EPMC5140776 | biostudies-literature
| S-EPMC4106919 | biostudies-literature
| S-EPMC3535517 | biostudies-literature