A method to prevent protein delocalization in imaging mass spectrometry of non-adherent tissues: application to small vertebrate lens imaging.


ABSTRACT: MALDI imaging requires careful sample preparation to obtain reliable, high-quality images of small molecules, peptides, lipids, and proteins across tissue sections. Poor crystal formation, delocalization of analytes, and inadequate tissue adherence can affect the quality, reliability, and spatial resolution of MALDI images. We report a comparison of tissue mounting and washing methods that resulted in an optimized method using conductive carbon substrates that avoids thaw mounting or washing steps, minimizes protein delocalization, and prevents tissue detachment from the target surface. Application of this method to image ocular lens proteins of small vertebrate eyes demonstrates the improved methodology for imaging abundant crystallin protein products. This method was demonstrated for tissue sections from rat, mouse, and zebrafish lenses resulting in good-quality MALDI images with little to no delocalization. The images indicate, for the first time in mouse and zebrafish, discrete localization of crystallin protein degradation products resulting in concentric rings of distinct protein contents that may be responsible for the refractive index gradient of vertebrate lenses.

SUBMITTER: Anderson DM 

PROVIDER: S-EPMC4379205 | biostudies-literature | 2015 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

A method to prevent protein delocalization in imaging mass spectrometry of non-adherent tissues: application to small vertebrate lens imaging.

Anderson David M G DM   Floyd Kyle A KA   Barnes Stephen S   Clark Judy M JM   Clark John I JI   Mchaourab Hassane H   Schey Kevin L KL  

Analytical and bioanalytical chemistry 20150210 8


MALDI imaging requires careful sample preparation to obtain reliable, high-quality images of small molecules, peptides, lipids, and proteins across tissue sections. Poor crystal formation, delocalization of analytes, and inadequate tissue adherence can affect the quality, reliability, and spatial resolution of MALDI images. We report a comparison of tissue mounting and washing methods that resulted in an optimized method using conductive carbon substrates that avoids thaw mounting or washing ste  ...[more]

Similar Datasets

| S-EPMC5425681 | biostudies-literature
| S-EPMC9276647 | biostudies-literature
| S-EPMC7508834 | biostudies-literature
| S-EPMC4392804 | biostudies-literature
2016-11-15 | GSE89818 | GEO
| S-EPMC8620134 | biostudies-literature
| S-EPMC2587601 | biostudies-literature
| S-EPMC6821845 | biostudies-literature
| S-EPMC8184062 | biostudies-literature
| S-EPMC3801209 | biostudies-literature